Search site

Institute of Medical and Biological Engineering

Professor J Fisher CBE

Image of person
email:j.fisher@leeds.ac.uk
tel:+44 (0)113 3432128
fax:+44 (0)113 344611
room:Engineering Building 312

Position

Professor of Mechanical Engineering

Responsibilities

Academic Background

Qualifications

BSc (Hons) 1st Class in Physics - Birmingham
Postgraduate Certificate in Design & Manufacture - Preston
PhD in Bioengineering - Glasgow
DEng - Leeds

Honours

Commander of the Order of the British Empire CBE

Professional Distinctions

Fellow, Institution of Mechanical Engineers - F.I.MECH.E.
Chartered Engineer, Engineering Council - C.Eng.
Chartered Scientist, Institute of Physics and Engineering in Medicine - CSci
Fellow, Institution of Physics and Engineering in Medicine - F.IPEM 

Research activities

Personal research interests lie primarily in the following areas:

Research Institute Membership

Research students

Professor Fisher CBE is currently supervising the following research student(s):

STUDENT THESIS TITLE
James Anderson Development of a patho-physiology based morphological model for avascular necrosis of the femoral head
Shuqiang An Computational modelling of fluid load support in articular cartilage
Divya Baji
Philippa Bowland
Hazel Fermor Engineering of natural cartilage substitution materials
Nicholas Gowland Wear and biological activity of antioxidant polyethylenes for total hip replacement
Dawn Groves The effect of the natural acetabulum's geometry on hip osteoarthritis: a clinical and tribological evaluation
Mark Hepples Development of a tissue engineering annuloplasty ring for atrioventricular valve reconstruction
Xijin Hua Biomechanisms and biotribology of artificial hip joints
Wei Jiang Wear measurement of polyethylene components in total knee replacement
Junyan Li Integrated computational biomechanics/biotribological modelling of natural hip joints
Carl Maguire Tissue engineering of osteochondral grafts from biological scaffolds application at the patellofemoral joint
Jake Milton-Barker Sterilisation techniques for small diameter acellular vascular grafts
Lucrezia Morticelli Guided functional re-engineering of the mitral valve
Rachel Pallan
Lindsey Parker
Normalina Sandora Regeneration of a cellular bone-ligament-tendon using adult mesenchymal stem
Mahsa Shahi Avadi
Carly Taylor The biotribology of articular cartilage in health and disease
Eirini Tsagkaraki Macroscale and microscale modelling of tissue engineering vascular grafts conditional under pulsatile flow
Vassilis Vayianos Soft-tissue in-growth into hard porous structures for ligament fixation in revision joint arthroplasties
Ammar Wahid
Ashley Ward

Selected publications

or you can display a briefer list

Journal Publications

Brockett CL; John G; Williams S; Isaac G; Jin Z; Fisher J Ceramic-on-carbon fibre reinforced poly-ether-ether ketone hip replacements: A novel low wear bearing. Journal of Biomedical Materials Research Part B: Applied Biomaterials, Accepted.
Bladen CL; Tzu-Yin L; Fisher J; Tipper JL In vitro analysis of the cytotoxic and anti-inflammatory effects of antioxidant compounds used as additives in ultra high-molecular weight polyethylene in total joint replacement components.. Journal of Biomedical Materials Research Part B : Applied Biomaterials, vol. 101, pp.407-413. 2013.LINK
DOI
Sariali E; Jin Z; Stewart T; Fisher J Spectral characterization of squeaking in ceramic-on-ceramic total hip arthroplasty: comparison of in vitro and in vivo values.. Journal of Orthopaedic Research, vol. 30, pp.185-189. 2012.LINK
DOI
Wilshaw SP; Rooney P; Berry H; Kearney JN; Homer-Vanniasinkam S; Fisher J; Ingham E Development and characterization of acellular allogeneic arterial matrices.. Tissue Engineering Part A, vol. 18, pp.471-483. 2012.LINK
DOI
Vicars R; Prokopovich P; Brown TD; Tipper JL; Ingham E; Fisher J; Hall RM The effect of anterior-posterior shear on the wear of CHARITÉ total disc replacement.. Spine (Phila Pa 1976), vol. 37, pp.E528-E534. 2012.LINK
DOI
Michalopoulos E; Knight RL; Korossis S; Kearney JN; Fisher J; Ingham E Development of methods for studying the differentiation of human mesenchymal stem cells under cyclic compressive strain.. Tissue Engineering Part C Methods, vol. 18, pp.252-262. 2012.LINK
DOI
Sariali E; Stewart T; Jin Z; Fisher J Effect of cup abduction angle and head lateral microseparation on contact stresses in ceramic-on-ceramic total hip arthroplasty.. Journal of Biomechanics, vol. 45, pp.390-393. 2012.LINK
DOI
Taylor SD; Tsiridis E; Ingham E; Jin Z; Fisher J; Williams S Comparison of human and animal femoral head chondral properties and geometries. Proceedings of the Institution of Mechanical Engineers Part H-Journal of Engineering in Medicine, vol. 226, pp.55-62. 2012.LINK
DOI
Meng Q; Liu F; Fisher J; Jin Z Contact mechanics and lubrication analyses of ceramic-on-metal total hip replacements. Tribology International, 2012.LINK
DOI
Brockett CL; Williams S; Jin Z; Fisher J; Isaac GH Squeaking Hip Arthroplasties. A Tribological Phenomenon. Journal of Arthroplasty, 2012.DOI
Burton A; Williams S; Brockett CL; Fisher J In vitro comparison of fixed- and mobile meniscal-bearing unicondylar knee arthroplasties: effect of design, kinematics, and condylar liftoff.. Journal of Arthroplasty, vol. 27, pp.1452-1459. 2012.LINK
DOI
Heiner AD; Callaghan JJ; Brown TD; Galvin AL; Fisher J Scratching Vulnerability of Conventional vs Highly Cross-Linked Polyethylene Liners Because of Large Embedded Third-Body Particles. Journal of Arthroplasty, vol. 27, pp.742-749. 2012.DOI
Ellison P; Tipper JL; Jennings LM; Fisher J Biological activity of polyethylene wear debris produced in the patellofemoral joint. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol. 226, pp.377-383. 2012.DOI
Liu F; Fisher J; Jin Z Effect of motion inputs on the wear prediction of artificial hip joints. Tribology International, 2012.DOI
Liu F; Fisher J; Jin Z Computational modelling of polyethylene wear and creep in total hip joint replacements: Effect of the bearing clearance and diameter. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 226, pp.552-563. 2012.LINK
DOI
Zhou X; Galvin AL; Jin Z; Yan X; Fisher J The influence of concave dimples on the metallic counterface on the wear of ultra-high molecular weight polyethylene. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 226, pp.455-462. 2012.LINK
DOI
Taylor SD; Ingham E; Jin Z; Fisher J; Williams S; Tsiridis E Comparison of human and animal femoral head chondral properties and geometries. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol. 226, pp.55-62. 2012.DOI
Brockett CL; Williams S; Jin Z; Isaac GH; Fisher J; John G Wear of ceramic-on-carbon fiber-reinforced poly-ether ether ketone hip replacements. Journal of Biomedical Materials Research - Part B Applied Biomaterials, vol. 100 B, pp.1459-1465. 2012.DOI
Burton A; Williams S; Brockett CL; Fisher J In Vitro Comparison of Fixed- and Mobile Meniscal-Bearing Unicondylar Knee Arthroplasties. Effect of Design, Kinematics, and Condylar Liftoff.. Journal of Arthroplasty, vol. 27, pp.1452-1459. 2012.DOI
Hyde P; Vicars R; Fisher J; Hall R Wear simulation of total disc arthroplasties: Sensitivity to device design and test parameters. Journal of ASTM International, vol. 9, 2012.
Vafaee T; Thomas D; Rooney P; Kearney J; Berry H; Korossis S; Jennings LM; Fisher J; Ingham E Decellularisation of allogeneic aortic and pulmonary valves using low concentration SDS. Journal of Tissue Engineering and Regenerative Medicine, vol. 6, pp.113-113. 2012.LINK
McLure SW; Fisher J; Conaghan PG; Williams S Regional cartilage properties of three quadruped tibiofemoral joints used in musculoskeletal research studies.. Proceedings of the Institution of Mechanical Engineers - Part H: Journal of Engineering in Medicine, vol. 226, pp.652-656. 2012.LINK
Fisher J; Al Hajjar M; Williams S; Tipper J; Ingham E; Jennings L (v) Simulation and measurement of wear in metal-on-metal bearings in vitro- understanding the reasons for increased wear. Orthopaedics and Trauma, vol. 26, pp.253-258. 2012.DOI
Jennings LM; Al-Hajjar M; Brockett CL; Williams S; Tipper JL; Ingham E; Fisher J (iv) Enhancing the safety and reliability of joint replacement implants. Orthopaedics and Trauma, vol. 26, pp.246-252. 2012.DOI
McLure SWD; Fisher J; Conaghan PG; Williams S Regional cartilage properties of three quadruped tibiofemoral joints used in musculoskeletal research studies. Proceedings of the Institution of Mechanical Engineers Part H-Journal of Engineering in Medicine, vol. 226, pp.652-656. 2012.LINK
DOI
Wang L; Williams S; Udofia I; Isaac G; Fisher J; Jin Z The effect of cup orientation and coverage on contact mechanics and range of motion of metal-on-metal hip resurfacing arthroplasty.. Proceedings of the Institution of Mechanical Engineers - Part H: Journal of Engineering in Medicine, vol. 226, pp.877-886. 2012.LINK
Fisher J A stratified approach to pre-clinical tribological evaluation of joint replacements representing a wider range of clinical conditions advancing beyond the current standard. Faraday Discussions, vol. 156, pp.59-68. 2012.DOI
Stapleton TW; Ingram J; Fisher J; Ingham E Investigation of the regenerative capacity of an acellular porcine medial meniscus for tissue engineering applications.. Tissue Engineering Part A, vol. 17, pp.231-242. 2011.LINK
DOI
Pawaskar SS; Ingham E; Fisher J; Jin Z Fluid load support and contact mechanics of hemiarthroplasty in the natural hip joint.. Medical Engineering and Physics, vol. 33, pp.96-105. 2011.LINK
DOI
Abdelgaied A; Liu F; Brockett C; Jennings L; Fisher J; Jin Z Computational wear prediction of artificial knee joints based on a new wear law and formulation.. Journal of Biomechanics, vol. 44, pp.1108-1116. 2011.LINK
DOI
Meng QE; Liu F; Fisher J; Jin ZM Transient elastohydrodynamic lubrication analysis of a novel metal-on-metal hip prosthesis with a non-spherical femoral bearing surface. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 225, pp.25-37. 2011.DOI
Liu F; Galvin A; Jin Z; Fisher J A new formulation for the prediction of polyethylene wear in artificial hip joints. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 225, pp.16-24. 2011.DOI
Fisher J; Ingham E How Engineering Provides Better Healthcare Medical Engineering Solutions for “Fifty active years after fifty.”. Science in Parliament, vol. 68, pp.22-23. 2011.
Pawaskar SS; Grosland NM; Ingham E; Fisher J; Jin Z Hemiarthroplasty of hip joint: An experimental validation using porcine acetabulum.. Journal of Biomechanics, vol. 44, pp.1536-1542. 2011.LINK
DOI
Lizhang J; Fisher J; Jin Z; Burton A; Williams S The effect of contact stress on cartilage friction, deformation and wear. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 225, pp.461-475. 2011.DOI
Brockett CL; Jennings LM; Fisher J The wear of fixed and mobile bearing unicompartmental knee replacements. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 225, pp.511-519. 2011.DOI
Prokopovich P; Perni S; Fisher J; Hall RM Spatial variation of wear on Charité lumbar discs.. Acta Biomater, vol. 7, pp.3914-3926. 2011.LINK
DOI
Fisher J Bioengineering reasons for the failure of metal-on-metal hip prostheses: an engineer's perspective.. Journal of Bone and Joint Surgery: British Volume, vol. 93, pp.1001-1004. 2011.LINK
DOI
Gao L; Fisher J; Tin Z Effect of walking patterns on the elastohydrodynamic lubrication of metal-on-metal total hip replacements. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 225, pp.515-525. 2011.DOI
Kheir E; Stapleton T; Shaw D; Jin Z; Fisher J; Ingham E Development and characterization of an acellular porcine cartilage bone matrix for use in tissue engineering.. Journal of Biomedical Materials Research. Part A, vol. 99, pp.283-294. 2011.LINK
DOI
Wang L; Korossis S; Fisher J; Ingham E; Jin ZM Prediction of Oxygen Distribution in Aortic Valve Leaflet Considering Diffusion and Convection. The Journal of Heart Valve Disease, vol. 20, pp.442-448. 2011.
Mak M; Jin Z; Fisher J; Stewart TD Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses.. Journal of Arthroplasty, vol. 26, pp.131-136. 2011.LINK
DOI
Heiner AD; Galvin AL; Fisher J; Callaghan JJ; Brown TD Scratching Vulnerability of Conventional vs Highly Cross-Linked Polyethylene Liners Because of Large Embedded Third-Body Particles. Journal of Arthroplasty, 2011.
Félix Quiñonez A; Summers JL; Fisher J; Jin ZM An analytical solution for the radial and tangential displacements on a thin hemispherical layer of articular cartilage.. Biomechanics and Modeling in Mechanobiology, vol. 10, pp.283-293. 2011.LINK
DOI
Sariali E; Stewart T; Mamoudy P; Jin Z; Fisher J Undetected fracture of an alumina ceramic on ceramic hip prosthesis.. Journal of Arthroplasty, vol. 25, pp.658.e1-658.e5. 2010.LINK
DOI
Luo Y; McCann L; Ingham E; Jin ZM; Ge S; Fisher J Polyurethane as a potential knee hemiarthroplasty biomaterial: an in-vitro simulation of its tribological performance. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 224, pp.415-425. 2010.DOI
Pawaskar SS; Fisher J; Jin ZM Robust and General Method for Determining Surface Fluid Flow Boundary Conditions in Articular Cartilage Contact Mechanics Modeling. Journal of Biomechanical Engineering, vol. 132, 2010.DOI
Meng Q; Gao L; Liu F; Yang P; Fisher J; Jin Z Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface.. Journal of Biomechanics, vol. 43, pp.849-857. 2010.LINK
DOI
Goreham-Voss CM; Hyde PJ; Hall RM; Fisher J; Brown TD Cross-shear implementation in sliding-distance-coupled finite element analysis of wear in metal-on-polyethylene total joint arthroplasty: Intervertebral total disc replacement as an illustrative application. Journal of Biomechanics, vol. 43, pp.1674-1681. 2010.DOI
Wang M; Radjenovic A; Stapleton TW; Venkatesh R; Williams S; Ingham E; Fisher J; Jin Z A novel and non-destructive method to examine meniscus architecture using 9.4 Tesla MRI.. Osteoarthritis and Cartilage, vol. 18, pp.1417-1420. 2010.LINK
DOI
Gao LM; Yang PR; Dymond I; Fisher J; Jin ZM Effect of surface texturing on the elastohydrodynamic lubrication analysis of metal-on-metal hip implants. Tribology International, vol. 43, pp.1851-1860. 2010.DOI
Al-Hajjar M; Leslie IJ; Tipper J; Williams S; Fisher J; Jennings LM Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic-on-ceramic total hip replacement.. Journal of Biomedical Materials Research Part B : Applied Biomaterials, vol. 95, pp.263-268. 2010.LINK
DOI
Yan Y; Neville A; Dowson D; Williams S; Fisher J Tribofilm formation in biotribocorrosion - does it regulate ion release in metal-on-metal artificial hip joints?. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 224, pp.997-1006. 2010.DOI
Galvin AL; Jennings LM; Tipper JL; Ingham E; Fisher J Wear and creep of highly crosslinked polyethylene against cobalt chrome and ceramic femoral heads. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 224, pp.1175-1183. 2010.DOI
Yan Y; Neville A; Dowson D; Williams S; Fisher J Electrochemical instrumentation of a hip simulator: a new tool for assessing the role of corrosion in metal-on-metal hip joints. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 224, pp.1267-1273. 2010.DOI
Gao LM; Meng QE; Liu F; Fisher J; Jin ZM The effect of aspherical geometry and surface texturing on the elastohydrodynamic lubrication of metal-on-metal hip prostheses under physiological loading and motions. Proceedings of the Institution of Mechanical Engineers Part C: Journal of Mechanical Engineering Science, vol. 224, pp.2627-2636. 2010.DOI
Ellison P; Fisher J Assessment of the damage in retrieved patellar components.. Journal of Long-Term Effects of Medical Implants, vol. 20, pp.57-72. 2010.LINK
Sariali E; Stewart T; Jin ZM; Fisher J Three-dimensional modeling of in vitro hip kinematics under micro-separation regime for ceramic on ceramic total hip prosthesis: An analysis of vibration and noise. Journal of Biomechanics, vol. 43, pp.326-333. 2010.DOI
Sariali E; Stewart T; Jin Z; Fisher J In vitro investigation of friction under edge-loading conditions for ceramic-on-ceramic total hip prosthesis.. Journal of Orthopaedic Research, vol. 28, pp.979-985. 2010.LINK
DOI
Fisher J; Jennings LM; Galvin AL; Jin ZM; Stone MH; Ingham E 2009 Knee Society Presidential Guest Lecture: Polyethylene wear in total knees.. Clinical Orthopaedics and Related Research, vol. 468, pp.12-18. 2010.LINK
DOI
Vicars R; Hyde PJ; Brown TD; Tipper JL; Ingham E; Fisher J; Hall RM The effect of anterior-posterior shear load on the wear of ProDisc-L TDR.. European Spine Journal, vol. 19, pp.1356-1362. 2010.LINK
DOI
Luo Y; Ge SR; Jin ZM; Fisher J Formation of titanium carbide coating with micro-porous structure. Applied Physics. A: Materials Science & Processing, vol. 98, pp.765-768. 2010.DOI
Figgitt M; Newson R; Leslie IJ; Fisher J; Ingham E; Case CP The genotoxicity of physiological concentrations of chromium (Cr(III) and Cr(VI)) and cobalt (Co(II)): An in vitro study. Mutation Research - Fundamental and Molecular Mechanisms of Mutagenesis, vol. 688, pp.53-61. 2010.DOI
Leslie IJ; Williams S; Brown C; Anderson J; Isaac G; Hatto P; Ingham E; Fisher J Surface engineering: a low wearing solution for metal-on-metal hip surface replacements.. Journal of Biomedical Materials Research Part B : Applied Biomaterials, vol. 90, pp.558-565. 2009.LINK
DOI
Yan Y; Neville A; Dowson D; Williams S; Fisher J The influence of swing phase load on the electrochemical response, friction, and ion release of metal-on-metal hip prostheses in a friction simulator. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 223, pp.303-309. 2009.DOI
Korossis S; Bolland F; Southgate J; Ingham E; Fisher J Regional biomechanical and histological characterisation of the passive porcine urinary bladder: Implications for augmentation and tissue engineering strategies.. Biomaterials, vol. 30, pp.266-275. 2009.LINK
DOI
Wilshaw SP; Burke D; Fisher J; Ingham E Investigation of the antiadhesive properties of human mesothelial cells cultured in vitro on implantable surgical materials.. Journal of Biomedical Materials Research Part B : Applied Biomaterials, vol. 88, pp.49-60. 2009.LINK
DOI
Harun MN; Wang FC; Jin ZM; Fisher J Long-term contact-coupled wear prediction for metal-on-metal total hip joint replacement. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 223, pp.993-1001. 2009.DOI
Isaac GH; Brockett C; Breckon A; van der Jagt D; Williams S; Hardaker C; Fisher J; Schepers A Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components.. Journal of Bone and Joint Surgery: British Volume, vol. 91, pp.1134-1141. 2009.LINK
DOI
Vicars R; Fisher J; Hall RM The accuracy and precision of a micro computer tomography volumetric measurement technique for the analysis of in-vitro tested total disc replacements.. Proceedings of the Institution of Mechanical Engineers - Part H: Journal of Engineering in Medicine, vol. 223, pp.383-388. 2009.LINK
Katta J; Jin Z; Ingham E; Fisher J Chondroitin sulphate: an effective joint lubricant?. Osteoarthritis and Cartilage, vol. 17, pp.1001-1008. 2009.LINK
DOI
Figueiredo-Pina CG; Dearnley PA; Fisher J UHMWPE wear response to apposing nitrogen S-phase coated and uncoated orthopaedic implant grade stainless steel. Wear, vol. 267, pp.743-752. 2009.DOI
McCann L; Ingham E; Jin Z; Fisher J An investigation of the effect of conformity of knee hemiarthroplasty designs on contact stress, friction and degeneration of articular cartilage: a tribological study.. Journal of Biomechanics, vol. 42, pp.1326-1331. 2009.LINK
DOI
Kang L; Galvin AL; Fisher J; Jin Z Enhanced computational prediction of polyethylene wear in hip joints by incorporating cross-shear and contact pressure in additional to load and sliding distance: effect of head diameter.. Journal of Biomechanics, vol. 42, pp.912-918. 2009.LINK
DOI
Yan Y; Neville A; Dowson D; Williams S; Fisher J Effect of metallic nanoparticles on the biotribocorrosion behaviour of Metal-on-Metal hip prostheses. Wear, vol. 267, pp.683-688. 2009.DOI
Galvin AL; Kang L; Udofia I; Jennings LM; McEwen HM; Jin Z; Fisher J Effect of conformity and contact stress on wear in fixed-bearing total knee prostheses.. Journal of Biomechanics, vol. 42, pp.1898-1902. 2009.LINK
DOI
Luo Y; Ge S; Jin Z; Fisher J Effect of surface modification on surface properties and tribological behaviours of titanium alloys. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 223, pp.311-316. 2009.DOI
Pourzal R; Theissmann R; Williams S; Gleising B; Fisher J; Fischer A Subsurface changes of a MoM hip implant below different contact zones. Journal of the Mechanical Behavior of Biomedical Materials, vol. 2, pp.186-191. 2009.DOI
Wang L; Wilshaw SP; Korossis S; Fisher J; Jin Z; Ingham E Factors influencing the oxygen consumption rate of aortic valve interstitial cells: application to tissue engineering.. Tissue Engineering Part C Methods, vol. 15, pp.355-363. 2009.LINK
DOI
Afsharpoya B; Barton DC; Fisher J; Purbach B; Wroblewski M; Stewart TD Cement mantle stress under retroversion torque at heel-strike.. Medical Engineering and Physics, vol. 31, pp.1323-1330. 2009.LINK
DOI
Katta J; Jin Z; Ingham E; Fisher J Effect of nominal stress on the long term friction, deformation and wear of native and glycosaminoglycan deficient articular cartilage.. Osteoarthritis and Cartilage, vol. 17, pp.662-668. 2009.LINK
DOI
Leslie IJ; Williams S; Isaac G; Ingham E; Fisher J High cup angle and microseparation increase the wear of hip surface replacements.. Clinical Orthopaedics and Related Research, vol. 467, pp.2259-2265. 2009.LINK
DOI
McCann L; Ingham E; Jin Z; Fisher J Influence of the meniscus on friction and degradation of cartilage in the natural knee joint.. Osteoarthritis and Cartilage, vol. 17, pp.995-1000. 2009.LINK
DOI
Katta J; Jin ZM; Ingham E; Fisher J Biotribology of articular cartilage-A review of the recent advances. Medical Engineering and Physics, vol. 30, pp.1349-1363. 2008.DOI
Kang L; Galvin AL; Brown TD; Jin ZM; Fisher J Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE. Journal of Biomechanics, vol. 41, pp.340-346. 2008.DOI
Stapleton TW; Ingram J; Katta J; Knight R; Korossis S; Fisher J; Ingham E Development and characterization of an acellular porcine medial meniscus for use in tissue engineering. Tissue Engineering: Part A, vol. 14, pp.505-518. 2008.DOI
Wang FC; Brockett C; Williams S; Udofia I; Fisher J; Jin ZM Lubrication and friction prediction in metal-on-metal hip implants.. Physics in Medicine and Biology, vol. 53, pp.1277-1293. 2008.LINK
DOI
Quinonez AF; Fisher J; Jin ZM A steady-state elastohydrodynamic lubrication model aimed at natural hip joints with physiological loading and anatomical position. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 222, pp.503-512. 2008.
Ellison P; Barton DC; Esler C; Shaw DL; Stone MH; Fisher J In vitro simulation and quantification of wear within the patellofemoral joint replacement.. Journal of Biomechanics, vol. 41, pp.1407-1416. 2008.LINK
DOI
Wang L; Korossis S; Ingham E; Fisher J; Jin ZM Computational Simulation of Oxygen Diffusion in Aortic Valve Leaflet for Tissue Engineering Applications. Journal of Heart Valve Disease, vol. 17, pp.700-709. 2008.
Williams S; Leslie I; Isaac G; Jin ZM; Ingham E; Fisher J Tribology and wear of metal-on-metal hip prostheses: Influence of cup angle and head position. Journal of Bone and Joint Surgery: American Volume, vol. 90A, pp.111-117. 2008.
Wilshaw SP; Kearney J; Fisher J; Ingham E Biocompatibility and potential of acellular human amniotic membrane to support the attachment and proliferation of allogeneic cells. Tissue Engineering: Part A, vol. 14, pp.463-472. 2008.DOI
Richards L; Brown C; Stone MH; Fisher J; Ingham E; Tipper JL Identification of nanometre-sized ultra-high molecular weight polyethylene wear particles in samples retrieved in vivo. Journal of Bone and Joint Surgery: British Volume, vol. 90B, pp.1106-1113. 2008.DOI
Figueiredo-Pina CG; Yan Y; Neville A; Fisher J Understanding the differences between the wear of metal-on-metal and ceramic-on-metal total hip replacements. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 222, pp.285-296. 2008.DOI
Dearnley PA; Pina CGF; Fisher J Assessment of S-phase coated medical grade stainless steel (Ortron 90) for use in the human joint replacement corrosion-wear environment. Journal of Physics D: Applied Physics, vol. 41, 2008.DOI
Papageorgiou I; Shadrick V; Davis S; Hails L; Schins R; Newson R; Fisher J; Ingham E; Case CP Macrophages detoxify the genotoxic and cytotoxic effects of surgical cobalt chrome alloy particles but not quartz particles on human cells in vitro. Mutation Research - Fundamental and Molecular Mechanisms of Mutagenesis, vol. 643, pp.11-19. 2008.DOI
Leslie I; Williams S; Brown C; Isaac G; Jin ZM; Ingham E; Fisher J Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements - An in vitro study. Journal of Biomedical Materials Research. Part B Applied Biomaterials, vol. 87B, pp.163-172. 2008.DOI
Galvin A; Jennings LM; McEwen HM; Fisher J The influence of tibial tray design on the wear of fixed-bearing total knee replacements. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 222, pp.1289-1293. 2008.DOI
Williams S; Isaac G; Porter N; Fisher J; Older J Long-term radiographic assessment of cemented polyethylene acetabular cups. Clinical Orthopaedics and Related Research, vol. 466, pp.366-372. 2008.
Liu F; Leslie I; Williams S; Fisher J; Jin Z Development of computational wear simulation of metal-on-metal hip resurfacing replacements.. Journal of Biomechanics, vol. 41, pp.686-694. 2008.LINK
DOI
Galvin A; Brockett C; Williams S; Hatto P; Burton A; Isaac G; Stone M; Ingham E; Fisher J Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 222, pp.1073-1080. 2008.DOI
Chen XM; Jin ZM; Fisher J Effect of albumin adsorption on friction between artificial joint materials. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 222, pp.513-521. 2008.
McCann L; Udofia I; Graindorge S; Ingham E; Jin Z; Fisher J Tribological testing of articular cartilage of the medial compartment of the knee using a friction simulator. Tribology International, vol. 41, pp.1126-1133. 2008.DOI
Kang L; Galvin AL; Brown TD; Fisher J; Jin ZM Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 222, pp.1049-1064. 2008.DOI
Knight RL; Wilcox HE; Korossis SA; Fisher J; Ingham E The use of acellular matrices for the tissue engineering of cardiac valves.. Proceedings of the Institution of Mechanical Engineers - Part H: Journal of Engineering in Medicine, vol. 222, pp.129-143. 2008.LINK
Katta J; Stapleton T; Ingham E; Jin ZM; Fisher J The effect of glycosaminoglycan depletion on the friction and deformation of articular cartilage.. Proceedings of the Institution of Mechanical Engineers - Part H: Journal of Engineering in Medicine, vol. 222, pp.1-11. 2008.LINK
Brockett CL; Harper P; Williams S; Isaac GH; Dwyer-Joyce RS; Jin Z; Fisher J The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements. Journal of Materials Science: Materials in Medicine, vol. 19, pp.1575-1579. 2008.
Derham C; Yow H; Ingram J; Fisher J; Ingham E; Korrosis SA; Homer-Vanniasinkam S Tissue engineering small-diameter vascular grafts: preparation of a biocompatible porcine ureteric scaffold.. Tissue Engineering Part A, vol. 14, pp.1871-1882. 2008.LINK
DOI
Brockett CL; Williams S; Jin ZM; Isaac G; Fisher J A comparison of friction in 28 mm conventional and 55 mm resurfacing metal-on-metal hip replacements. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 221, pp.391-398. 2007.
Papageorgiou I; Brown C; Schins R; Singh S; Newson R; Davis S; Fisher J; Ingham E; Case CP The effect of nano- and micron-sized particles of cobalt-chromium alloy on human fibroblasts in vitro. Biomaterials, vol. 28, pp.2946-2958. 2007.DOI
Bell CJ; Fisher J Simulation of polyethylene wear in ankle joint prostheses. Journal of Biomedical Materials Research. Part B Applied Biomaterials, vol. 81B, pp.162-167. 2007.DOI
Pina CGF; Dahm KL; Fisher J; Dearnley PA The damage tolerance of S-phase coated biomedical grade stainless steel. Wear, vol. 263, pp.1081-1086. 2007.DOI
Northwood E; Fisher J Erratum to "A multi-directional in vitro investigation into friction, damage and wear of innovative chondroplasty materials against articular cartilage" (vol 22, pg 834, 2007). Clinical Biomechanics, vol. 22, pp.1132-1132. 2007.DOI
Williams S; Schepers A; Isaac G; Hardaker C; Ingham E; van der Jagt D; Breckon A; Fisher J The 2007 Otto Aufranc Award - Ceramic-on-metal hip arthroplasties - A comparative in vitro and in vivo study. Clinical Orthopaedics and Related Research, pp.23-32. 2007.
Papageorgiou I; Brown C; Schins R; Singh S; Newson R; Davis S; Fisher J; Ingham E; Case CP The effect of nano- and micron-sized particles of cobalt-chromium alloy on human fibroblasts in vitro . Biomaterials, vol. 28, pp.2946-2958. 2007.DOI
Brockett C; Williams S; Jin Z; Isaac G; Fisher J Friction of total hip replacements with different bearings and loading conditions.. Journal of Biomedical Materials Research Part B : Applied Biomaterials, vol. 81, pp.508-515. 2007.LINK
DOI
Plainfosse M; Hatton PV; Crawford A; Jin Z; Fisher J Influence of the extracellular matrix on the frictional properties of tissue-engineered cartilage. Biochemical Society Transactions, vol. 35, pp.677-679. 2007.
Jennings LM; Bell CJ; Ingham E; Komistek RD; Stone MH; Fisher J The influence of femoral condylar lift-off on the wear of artificial knee joints. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 221, pp.305-314. 2007.DOI
Bolland F; Korossis S; Wilshaw S; Ingham E; Fisher J; Kearney JN; Southgate J Development and characterisation of a full-thickness acellular porcine bladder matrix for tissue engineering. Biomaterials, vol. 28, pp.1061-1070. 2007.DOI
Oswal D; Korossis S; Mirsadraee S; Wilcox H; Watterson K; Fisher J; Ingham E Biomechanical characterization of decellularized and cross-linked bovine pericardium.. The Journal of Heart Valve Disease, vol. 16, pp.165-174. 2007.LINK
Mirsadraee S; Wilcox HE; Watterson KG; Kearney JN; Hunt J; Fisher J; Ingham E Biocompatibility of acellular human pericardium. Journal of Surgical Research, vol. 143, pp.407-414. 2007.DOI
Brown C; Williams S; Tipper JL; Fisher J; Ingham E Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation. Journal of Materials Science: Materials in Medicine, vol. 18, pp.819-827. 2007.DOI
Katta J; Pawaskar SS; Jin ZM; Ingham E; Fisher J Effect of load variation on the friction properties of articular cartilage. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 221, pp.175-181. 2007.
Galvin AL; Tipper IL; Jennings LM; Stone MH; Jin ZM; Ingham E; Fisher J Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations . Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, 2007.
Northwood E; Fisher J A multi-directional in vitro investigation into friction, damage and wear of innovative chondroplasty materials against articular cartilage. Clinical Biomechanics, vol. 22, pp.834-842. 2007.DOI
Carrick LM; Aggeli A; Boden N; Fisher J; Ingham E; Waigh TA Effect of ionic strength on the self-assembly, morphology and gelation of pH responsive beta-sheet tape-forming peptides. Tetrahedron, vol. 63, pp.7457-7467. 2007.DOI
Pawaskar SS; Jin ZM; Fisher J Modelling of fluid support inside articular cartilage during sliding. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 221, pp.165-174. 2007.DOI
Ingram JH; Korossis S; Howling G; Fisher J; Ingham E The use of ultrasonication to aid recellularization of acellular natural tissue scaffolds for use in anterior cruciate ligament reconstruction.. Tissue Engineering, vol. 13, pp.1561-1572. 2007.LINK
DOI
Northwood E; Fisher J; Kowalski R Investigation of the friction and surface degradation of innovative chondroplasty materials against articular cartilage. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 221, pp.263-279. 2007.DOI
Oswal D; Korossis S; Mirsadraee S; Wilcox HE; Watterson KG; Fisher J; Ingham E Biomechanical characterisation of decellularised and cross linked bovine pericardium. European Cells and Materials, vol. 11, pp.76. 2006.
Graindorge S; Ferrandez W; Jin ZM; Ingham E; Fisher J The natural synovial joint: a finite element investigation of biphasic surface amorphous layer lubrication under dynamic loading conditions. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 220, pp.671-681. 2006.DOI
Williams S; Jalali-Vahid D; Brockett C; Jin Z; Stone MH; Ingham E; Fisher J Effect of swing phase load on metal-on-metal hip lubrication, friction and wear.. Journal of Biomechanics, vol. 39, pp.2274-2281. 2006.LINK
DOI
Forsey RW; Fisher J; Thompson J; Stone MH; Bell CJ; Ingham E The effect of hyaluronic acid and phospholipid based lubricants on friction within a human cartilage damage model. Biomaterials, vol. 27, pp.4581-4590. 2006.DOI
Jin ZM; Stone M; Ingham E; Fisher J Biotribology. Current Orthopaedics, vol. 20, pp.32-40. 2006.DOI
Korossis S; Bolland F; Ingham E; Fisher J; Kearney J; Southgate J Tissue engineering of the urinary bladder: Considering structure-function relationships and the role of mechanotransduction. Tissue Engineering, vol. 12, pp.635-644. 2006.
Yow K; Korossis S; Ingram JH; Ingham E; Fisher J; Homer-Vanniasinkam S Tissue engineering of vascular conduits. British Journal of Surgery, vol. 93, pp.652-661. 2006.DOI
Bell CJ; Carrick LM; Katta J; Jin Z; Ingham E; Aggeli A; Boden N; Waigh TA; Fisher J Self-assembling peptides as injectable lubricants for osteoarthritis.. Journal of Biomedical Materials Research. Part A, vol. 78, pp.236-246. 2006.LINK
DOI
Tipper JL; Galvin AL; Ingham E; Fisher J Estimation of the osteolytic potential of non-crosslinked and crosslinked polyethylene’s and ceramic-on-ceramic total hip prostheses. Journal of ASTM International , vol. 3, pp.1-16. 2006.DOI
Galvin A; Kang L; Tipper J; Stone M; Ingham E; Jin ZM; Fisher J Wear of crosslinked polyethylene under different tribological conditions. Journal of Materials Science: Materials in Medicine, vol. 17, pp.235-243. 2006.DOI
Jin Z; Williams S; Tipper JL; Ingham E; Fisher J Tribology of hip joints from natural hip joints, cartilage substitution, artificial replacements to cartilage tissue engineering. Journal of Biomechanical Science and Engineering, vol. 1, pp.69-81. 2006.
Wilshaw SP; Kearney JN; Fisher J; Ingham E Production of an acellular amniotic membrane matrix for use in tissue engineering.. Tissue Engineering, vol. 12, pp.2117-2129. 2006.LINK
DOI
Mirsadraee S; Wilcox HE; Korossis SA; Kearney JN; Watterson KG; Fisher J; Ingham E Development and characterization of an acellular human pericardial matrix for tissue engineering. Tissue Engineering, vol. 12, pp.763-773. 2006.
Isaac GH; Thompson J; Williams S; Fisher J Metal-on-metal bearings surfaces: materials, manufacture, design, optimization, and alternatives. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 220, pp.119-133. 2006.DOI
Bell CJ; Ingham E; Fisher J Influence of hyaluronic acid on the time-dependent friction response of articular cartilage under different conditions. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 220, pp.23-31. 2006.DOI
Kang L; Galvin AL; Jin ZM; Fisher J A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 220, pp.33-46. 2006.DOI
Fisher J; McEwen H; Tipper J; Jennings L; Farrar R; Stone M; Ingham E Wear-simulation analysis of rotating-platform mobile-bearing knees.. Orthopedics, vol. 29, pp.S36-S41. 2006.LINK
Korossis S; Bolland F; Kearney JN; Southgate J; Ingham E; Fisher J Characterization of the regional biomechanics of the urinary bladder. Journal of Biomechanics, vol. 39, pp.S391. 2006.
Tipper JL; Galvin AL; Williams S; McEwen HM; Stone MH; Ingham E; Fisher J Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators.. Journal of Biomedical Materials Research. Part A, vol. 78, pp.473-480. 2006.LINK
DOI
Wang F; Brockett C; Williams S; Jin Z; Fisher J Lubrication modelling and friction prediction in metal-on-metal hip Jjoint implants. Journal of Biomechanics, vol. 39, pp.139. 2006.
Hall RM; Brown TD; Fisher J; Ingham E; Mendoza SA; Mayer HM Introduction to lumbar total disc replacement: factors that affect tribological performance. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 220, pp.775-786. 2006.DOI
Graindorge S; Ferrandez W; Ingham E; Jin Z; Twigg P; Fisher J The role of the surface amorphous layer of articular cartilage in joint lubrication. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 220, pp.597-607. 2006.DOI
Fisher J; Jin ZM; Tipper J; Stone M; Ingham E Presidential guest lecture - Tribology of alternative beatings. Clinical Orthopaedics and Related Research, pp.25-34. 2006.DOI
Ingham E; Fisher J The role of macrophages in osteolysis of total joint replacement. Biomaterials, vol. 26, pp.1271-1286. 2005.
Clarke MT; Darrah C; Stewart TD; Ingham E; Fisher J; Nolan JF Long-term clinical, radiological and histopathological follow-up of a well-fixed McKee-Farrar metal-on-metal total hip arthroplasty. Journal of Arthroplasty, vol. 20, pp.542-546. 2005.
Tipper JL; Ingham E; Jin Z; Fisher J The science of metal-on-metal articulation . Current Orthopaedics, vol. 19, pp.280-287. 2005.DOI
Tipper JL; Ingham E; Jin Z; Fisher J The science of metal-on-metal articulation. Current Orthopaedics, vol. 19, pp.280-287. 2005.DOI
Graindorge S; Ferrandez W; Jin ZM; Ingham E; Grant C; Twigg P; Fisher J Biphasic surface amorphous layer lubrication of articular cartilage. Medical Engineering and Physics, vol. 27, pp.836-844. 2005.DOI
Ingram JH; Kowalski R; Fisher J; Ingham E The osteolytic response of macrophages to challenge with particles of simplex P, endurance, palacos R, and vertebroplastic bone cement particles in vitro. Journal of Biomedical Materials Research. Part B Applied Biomaterials, vol. 75B, pp.210-220. 2005.
Galvin AL; Tipper JL; Ingham E; Fisher J Nanometre size wear debris generated from crosslinked and non-crosslinked ultra high molecular weight polyethylene in artificial joints. Wear, vol. 259, pp.977-983. 2005.DOI
Wilcox HE; Korossis S; Booth C; Watterson KG; Kearney JN; Fisher J; Ingham E Biocompatibility and recellularization potential of an acellular porcine heart valve matrix. The Journal of Heart Valve Disease, vol. 14, pp.228-237. 2005.
Kamali A; Farrar R; Hatto P; Stone MH; Fisher J Wear of ultrahigh-molecular-weight polyethylene against titanium-nitride-coated counterfaces. Proceedings of the Institution of Mechanical Engineers Part J: Journal of Engineering Tribology, vol. 219, pp.41-47. 2005.DOI
Knight RL; Booth C; Wilcox HE; Fisher J; Ingham E Tissue engineering of cardiac valves: Re-seeding of acellular porcine aortic valve matrices with human mesenchymal progenitor cells. The Journal of Heart Valve Disease, vol. 14, pp.806-813. 2005.
Mirsadraee S; Wilcox HE; Korossis SA; Kearney JN; Fisher J; Ingham E Tissue engineered human pericardium: a potential decellularised matrix for bladder wall augmentation. BJU International, vol. 95, pp.66-66. 2005.
Galvin AL; Williams S; Hatto P; Thompson J; Isaac GH; Stone MH; Ingham E; Fisher J Comparison of wear of ultra high molecular weight polyethylene acetabular cups against alumina ceramic and chromium nitride coated femoral heads. Wear, vol. 259, pp.972-976. 2005.DOI
Korossis SA; Wilcox HE; Watterson KG; Kearney JN; Ingham E; Fisher J In-vitro assessment of the functional performance of the decellularized intact porcine aortic root. The Journal of Heart Valve Disease, vol. 14, pp.408-421. 2005.
Carrick L; Tassieri M; Waigh TA; Aggeli A; Boden N; Bell C; Fisher J; Ingham E; Evans RML The internal dynamic modes of charged self-assembled peptide fibrils. Langmuir, vol. 21, pp.3733-3737. 2005.DOI
McEwen HM; Barnett PI; Bell CJ; Farrar R; Auger DD; Stone MH; Fisher J The influence of design, materials and kinematics on the in vitro wear of total knee replacements.. Journal of Biomechanics, vol. 38, pp.357-365. 2005.LINK
DOI
Wilcox HE; Korossis SA; Booth C; Watterson KG; Kearney JN; Fisher J; Ingham E Biocompatibility and recellularization potential of an acellular porcine heart valve matrix. Journal of Heart Valve Disease, vol. 14, pp.228-237. 2005.
Korossis S; Wilcox HE; Watterson KG; Kearney JN; Ingham E; Fisher J In-Vitro Assessment of the Functional Performance of the Decellularized Intact Porcine Aortic Root. The Journal of Heart Valve Disease, vol. 14, pp.408-422. 2005.
Ingham E; Fisher J The role of macrophages in osteolysis of total joint replacement. Biomaterials, vol. 26, pp.1271-1286. 2005.DOI
Wilcox HE; Korossis SA; Booth C; Watterson KG; Kearney JN; Fisher J; Ingham E Biocompatibility and recellularization potential of an acellular porcine heart valve matrix.. The Journal of Heart Valve Disease, vol. 14, pp.228-236. 2005.LINK
Nevelos J; Shelton JC; Fisher J Metallurgical considerations in the wear of metal-on-metal hip bearings. Hip International, vol. 14, pp.1-10. 2004.
Williams S; Stewart TD; Ingham E; Stone MH; Fisher J Metal-on-metal bearing wear with different swing phase loads. Journal of Biomedical Materials Research. Part B Applied Biomaterials, vol. 70B, pp.233-239. 2004.DOI
Lomas RJ; Jennings LM; Fisher J; Kearney JN Effects of a Peracetic Acid Disinfection Protocol on the Biocompatibility and Biomechanical Properties of Human Patellar Tendon Allografts. Cell and Tissue Banking, vol. 5, pp.149-160. 2004.DOI
Williams S; Isaac G; Hatto P; Stone MH; Ingham E; Fisher J Comparative wear under different conditions of surface-engineered metal-on-metal bearings for total hip arthroplasty. Journal of Arthroplasty, vol. 19, pp.112-117. 2004.
Reid SA; Walker PG; Fisher J; Nagy ZL; Ridgway JP; Sivananthan MU; Watterson KG Quantification of pulmonary autograft characteristics using magnetic resonance imaging.. The Journal of Heart Valve Disease, vol. 13, pp.78-85. 2004.LINK
Fisher J; McEwen HMJ; Tipper JL; Galvin AL; Ingram J; Kamali A; Stone MH; Ingham E Wear, debris, and biologic activity of cross-linked polyethylene in the knee - Benefits and potential concerns. Clinical Orthopaedics and Related Research, pp.114-119. 2004.
Ingram JH; Stone M; Fisher J; Ingham E The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles.. Biomaterials, vol. 25, pp.3511-3522. 2004.LINK
DOI
Fisher J; McEwen HM; Barnett PI; Bell C; Stone MH; Ingham E Influences of sterilising techniques on polyethylene wear.. The Knee, vol. 11, pp.173-176. 2004.LINK
DOI
Hu XQ; Isaac GH; Fisher J Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses.. Bio-Medical Materials and Engineering, vol. 14, pp.145-149. 2004.LINK
Macdonald W; Campbell P; Fisher J; Wennerberg A Variation in surface texture measurements. Journal of Biomedical Materials Research. Part B Applied Biomaterials, vol. 70B, pp.262-269. 2004.DOI
Fisher J; Hu XQ; Stewart TD; Williams S; Tipper JL; Ingham E; Stone MH; Davies C; Hatto P; Bolton J; Riley M; Hardaker C; Isaac GH; Berry G Wear of surface engineered metal-on-metal hip prostheses. Journal of Materials Science: Materials in Medicine, vol. 15, pp.225-235. 2004.
Mohanraj J; Stewart TD; Wellings S; Jones RA; Thompson S; Ward IM; Fisher J The wear and fracture behaviour of ultra high molecular weight polyethylene subjected to gamma-irradiation in an atmosphere of acetylene.. Journal of Materials Science: Materials in Medicine, vol. 15, pp.1339-1347. 2004.LINK
DOI
Howling GI; Ingham E; Sakoda H; Stewart TD; Fisher J; Antonarulrajah A; Appleyard S; Rand B Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris.. Journal of Materials Science: Materials in Medicine, vol. 15, pp.91-98. 2004.LINK
Germain MA; Hatton A; Williams S; Matthews JB; Stone MH; Fisher J; Ingham E Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro.. Biomaterials, vol. 24, pp.469-479. 2003.LINK
Wang FC; Jin Z; McEwen HMJ; Fisher J Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 217, pp.477-490. 2003.
Fisher J; Hu XQ; Williams S; Tipper JL; Ingham E; Stone MH; Hatto P; Berry G; Hardaker C; Isaac GH New Bearing Surfaces : What does the future hold?. Seminars in Arthroplasty, vol. 14, pp.131-139. 2003.
Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.. Proceedings of the Institution of Mechanical Engineers - Part H: Journal of Engineering in Medicine, vol. 217, pp.147-153. 2003.LINK
Korossis S; Wilcox HE; Watterson K; Kearney JN; Ingham E; Fisher J Hydrodynamic characterisation of the decellularised intact porcine aortic valve. , pp.288-296. 2003.
Stewart TD; Tipper JL; Insley G; Streicher RM; Ingham E; Fisher J Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation. Journal of Biomedical Materials Research. Part B Applied Biomaterials, vol. 66B, pp.567-573. 2003.DOI
D'Souza S; Butterfield M; Fisher J Kinematics of synthetic flexible heart valves during accelerated testing. The Journal of Heart Valve Disease, vol. 12, pp.110-120. 2003.
Hanson BM; Levesley MC; Fisher J Using self-sensing techniques to produce a small, robust, inexpensive rheometer. Applied Rheology, vol. 13, pp.242-250. 2003.
Ingham E; Fisher J; Stone MH Wear of historical polyethylenes in hip prostheses. Biomechanical success and a biological failure. Hip International, vol. 13 , pp.17-27. 2003.
Fisher J; Ingham E; Stone MH Alternate bearing couples in total hip replacements: Solutions for young patients. Hip International, vol. 13, pp.31-35. 2003.
Korossis S; Wilcox HE; Booth C; Watterson KG; Kearney JN; Ingham E; Fisher J Biomechanical and hydrodynamic characterisation of decellularised intact porcine aortic valves for tissue engineering. Tissue Engineering, vol. 9, pp.838. 2003.
Stewart TD; Tipper JL; Insley G; Streicher RM; Ingham E; Fisher J Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation. Journal of Arthroplasty, vol. 18, pp.726-734. 2003.DOI
Howling GI; Sakoda H; Antonarulrajah A; Marrs H; Stewart TD; Appleyard S; Rand B; Fisher J; Ingham E Biological response to wear debris generated in carbon based composites as potential bearing surfaces for artificial hip joints. Journal of Biomedical Materials Research. Part B Applied Biomaterials, vol. 67B, pp.758-764. 2003.DOI
Mitchell W; Matthews JB; Stone MH; Fisher J; Ingham E Comparison of the response of human peripheral blood mononuclear cells to challenge with particles of three bone cements in vitro. Biomaterials, vol. 24, pp.737-748. 2003.
Shardlow DL; Stone MH; Ingham E; Fisher J Cement particles containing radio-opacifiers stimulate pro-osteolytic cytokine production from a human monocytic cell line.. Journal of Bone and Joint Surgery: British Volume, vol. 85, pp.900-905. 2003.LINK
Hatton A; Nevelos JE; Matthews JB; Fisher J; Ingham E Effects of clinically relevant alumina ceramic wear particles on TNF-alpha production by human peripheral blood mononuclear phagocytes. Biomaterials, vol. 24, pp.1193-1204. 2003.
Williams S; Tipper JL; Ingham E; Stone MH; Fisher J In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements.. Proceedings of the Institution of Mechanical Engineers - Part H: Journal of Engineering in Medicine, vol. 217, pp.155-163. 2003.LINK
Besong A; Jin Z; Fisher J Importance of pin geometry on pin-on-plate wear testing of hard-on-hard bearing materials for artificial hip joints. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 215, pp.605-610. 2002.
Booth C; Korossis SA; Wilcox HE; Watterson KG; Kearney JN; Fisher J; Ingham E Tissue engineering of cardiac valve prostheses I: development and histological characterization of an acellular porcine scaffold.. The Journal of Heart Valve Disease, vol. 11, pp.457-462. 2002.LINK
Mak MM; Besong AA; Jin Z; Fisher J Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 216, pp.403-408. 2002.
Korossis SA; Booth C; Wilcox HE; Watterson KG; Kearney JN; Fisher J; Ingham E Tissue engineering of cardiac valve prostheses II: Biomechanical characterization of decellularized porcine aortic heart valves. Journal of Heart Valve Disease, vol. 11, pp.463-471. 2002.
Reid SA; Walker PG; Fisher J; Nagy Z; Ridgway JP; Watterson KG; Sivananthan MU The quantification of pulmonary valve haemodynamics using MRI.. The International Journal of Cardiovascular Imaging, vol. 18, pp.217-225. 2002.LINK
Bell J; Tipper JL; Ingham E; Stone MH; Wroblewski BM; Fisher J Quantitative analysis of UHMWPE wear debris isolated from the periprosthetic femoral tissues from a series of Charnley total hip arthroplasties. Bio-Medical Materials and Engineering, vol. 12, pp.189-202. 2002.
Tipper JL; Hatton A; Nevelos JE; Ingham E; Doyle C; Streicher R; Nevelos AB; Fisher J Alumina-alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulations. Biomaterials, vol. 23, pp.3441-3448. 2002.
Ingram J; Matthews JB; Tipper J; Stone M; Fisher J; Ingham E Comparison of the biological activity of grade GUR 1120 and GUR 415HP UHMWPE wear debris. Bio-Medical Materials and Engineering, vol. 12, pp.177-188. 2002.
Jennings LM; El-Gatit A; Nagy ZL; Fisher J; Walker PG; Watterson KG Hydrodynamic function of the second-generation mitroflow pericardial bioprosthesis. Annals of Thoracic Surgery, vol. 74, pp.63-68. 2002.
Fisher J; Hu XQ; Tipper JL; Stewart TD; Williams S; Stone MH; Davies C; Hatto P; Bolton J; Riley M; Hardaker C; Isaac GH; Berry G; Ingham E An in vitro study of the reduction in wear of metal-on-metal hip prostheses using surface-engineered femoral heads.. Proceedings of the Institution of Mechanical Engineers - Part H: Journal of Engineering in Medicine, vol. 216, pp.219-230. 2002.LINK
Barnett PI; McEwen HMJ; Auger DD; Stone MH; Ingham E; Fisher J Investigation of wear of knee prostheses in a new displacement/force-controlled simulator. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 216, pp.51-62. 2002.
Endo M; Tipper JL; Barton DC; Stone MH; Ingham E; Fisher J Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses.. Proceedings of the Institution of Mechanical Engineers - Part H: Journal of Engineering in Medicine, vol. 216, pp.111-122. 2002.LINK
Blunn G; Brach de Preva EM; Costa L; Fisher J; Freeman MAR Ultrahigh molecular weight polyethylene (UHMWPE) in total knee replacement: Fabrication, sterilisation and wear. Journal of Bone and Joint Surgery: British Volume, vol. 84-B, pp.946-949. 2002.
Hatton A; Nevelos JE; Nevelos AA; Banks RE; Fisher J; Ingham E Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision.. Biomaterials, vol. 23, pp.3429-3440. 2002.LINK
Fisher J Untitled - In reply. Journal of Arthroplasty, vol. 17, pp.1078-1079. 2002.DOI
Nevelos JE; Ingham E; Doyle C; Nevelos AB; Fisher J The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator.. Journal of Materials Science: Materials in Medicine, vol. 12, pp.141-144. 2001.LINK
Sakoda H; Fisher J; Lu S; Buchanan F The effect of accelerated aging on the wear of UHMWPE.. Journal of Materials Science: Materials in Medicine, vol. 12, pp.1043-1047. 2001.LINK
Voice AM; Vale MC; Fisher J A depth profile of oxidation and gel fraction in gamma-irradiated silane crosslinked and ultra high molecular weight polyethylenes. Bio-Medical Materials and Engineering, vol. 11, pp.37-41. 2001.
Firkins PJ; Tipper JL; Ingham E; Stone MH; Farrar R; Fisher J A novel low wearing differential hardness, ceramic-on-metal hip joint prosthesis. Journal of Biomechanics, vol. 34, pp.1291-1298. 2001.
Howling GI; Barnett PI; Tipper JL; Stone MH; Fisher J; Ingham E Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants.. Journal of Biomedical Materials Research, vol. 58, pp.415-420. 2001.LINK
Nevelos JE; Ingham E; Doyle C; Nevelos AB; Fisher J Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions.. Biomaterials, vol. 22, pp.2191-2197. 2001.LINK
Jones VC; Barton DC; Auger DD; Hardaker C; Stone MH; Fisher J Simulation of tibial counterface wear in mobile bearing knees with uncoated and ADLC coated surfaces. Bio-Medical Materials and Engineering, vol. 11, pp.105-115. 2001.
Mcgrath LR; Shardlow DL; Ingham E; Andrews M; Ivory J; Stone MH; Fisher J A retrieval study of capital hip prostheses with titanium alloy femoral stems.. Journal of Bone and Joint Surgery: British Volume, vol. 83, pp.1195-1201. 2001.LINK
Fisher J; McEwen H; Barnett PI; Bell CJ; Stewart TD; Stone MH; Ingham E Wear of polyethylene in artificial knee joints. Current Orthopaedics, vol. 15, pp.399-405. 2001.DOI
Sakoda H; Voice AM; McEwen HMJ; Isaac GH; Hardaker C; Wroblewski BM; Fisher J A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene. Journal of Arthroplasty, vol. 16, pp.1018-1023. 2001.
Jones VC; Williams IR; Auger DD; Walsh W; Barton DC; Stone MH; Fisher J Quantification of third body damage to the tibial counterface in mobile bearing knees. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 215, pp.171-179. 2001.
Nevelos JE; Prudhommeaux F; Hamadouche M; Doyle C; Ingham E; Meunier A; Nevelos AB; Sedel L; Fisher J Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening.. Journal of Bone and Joint Surgery: British Volume, vol. 83, pp.598-603. 2001.LINK
Matthews JB; Green TR; Stone MH; Wroblewski BM; Fisher J; Ingham E Comparison of the response of three human monocytic cell lines to challenge with polyethylene particles of known size and dose. Journal of Materials Science: Materials in Medicine, vol. 12, pp.249-258. 2001.
Fisher J Untitled - In reply. Journal of Arthroplasty, vol. 16, pp.1086-1087. 2001.
Stewart T; Tipper J; Streicher R; Ingham E; Fisher J Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions.. Journal of Materials Science: Materials in Medicine, vol. 12, pp.1053-1056. 2001.LINK
Fisher J; Bell J; Barbour PSM; Tipper JL; Matthews JB; Besong AA; Stone MH; Ingham E A novel method for the prediction of functional biological activity of polyethylene wear debris. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 215, pp.127-132. 2001.
Firkins PJ; Tipper JL; Ingham E; Stone MH; Farrar R; Fisher J Influence of simulator kinematics on the wear of metal-on-metal hip prostheses. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 215, pp.119-122. 2001.
Tipper JL; Firkins PJ; Besong AA; Barbour PSM; Nevelos J; Stone MH; Ingham E; Fisher J Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator. Wear, vol. 250, pp.120-128. 2001.
Butterfield M; Wheatley DJ; Williams DF; Fisher J A new design for polyurethane heart valves. The Journal of Heart Valve Disease, vol. 10, pp.105-110. 2001.
Fisher J; Vale MC; Voice AM A depth profile of oxidation and gel fraction in gamma-irradiated silane crosslinked and ultra high molecular weight polyethylenes. Bio-Medical Materials and Engineering, vol. 11, pp.37-42. 2001.
Barnett PI; Fisher J; Auger DD; Stone MH; Ingham E Comparison of wear in a total knee replacement under different kinematic conditions. Journal of Materials Science: Materials in Medicine, vol. 12, pp.1039-1042. 2001.
Marrs H; Barton DC; Doyle C; Jones RA; Lewis EL; Ward IM; Fisher J The effect of molecular orientation and acetylene-enhanced crosslinking on the wear of UHMWPE in total artificial joints.. Journal of Materials Science: Materials in Medicine, vol. 12, pp.621-628. 2001.LINK
Wheatley DJ; Bernacca GM; Tolland MM; O'Connor B; Fisher J; Williams DF Hydrodynamic function of a biostable polyurethane flexible heart valve after six months in sheep. The International Journal of Artificial Organs, vol. 24, pp.95-101. 2001.
Matthews JB; Mitchell W; Stone MH; Fisher J; Ingham E A novel three-dimensional tissue equivalent model to study the combined effects of cyclic mechanical strain and wear particles on the osteolytic potential of primary human macrophages in vitro.. Proceedings of the Institution of Mechanical Engineers - Part H: Journal of Engineering in Medicine, vol. 215, pp.479-486. 2001.LINK
Bell J; Tipper JL; Ingham E; Stone MH; Fisher J The influence of phospholipid concentration in protein-containing lubricants on the wear of ultra-high molecular weight polyethylene in artificial hip joints. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 215, pp.259-264. 2001.
Jennings LM; Butterfield M; Walker PG; Watterson KG; Fisher J The influence of ventricular input impedance on the hydrodynamic performance of bioprosthetic aortic roots in vitro.. The Journal of Heart Valve Disease, vol. 10, pp.269-275. 2001.LINK
Firkins PJ; Tipper JL; Saadatzadeh MR; Ingham E; Stone MH; Farrar R; Fisher J Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested In a physiological hip joint simulator. Bio-Medical Materials and Engineering, vol. 11, pp.143-157. 2001.
Endo MM; Barbour PS; Barton DC; Fisher J; Tipper JL; Ingham E; Stone MH Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.. Bio-Medical Materials and Engineering, vol. 11, pp.23-35. 2001.LINK
Bell J; Besong AA; Tipper JL; Ingham E; Wroblewski BM; Stone MH; Fisher J Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 214, pp.513-518. 2000.
Fisher J Investigation into the tribological condition of acetabular tissue after bipolar joint replacement hip surgery. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 214, pp.361-370. 2000.
Matthews JB; Green TR; Stone MH; Wroblewski BM; Fisher J; Ingham E Comparison of the response of primary murine peritoneal macrophages and the U937 human histiocytic cell line to challenge with in vitro generated clinically relevant UHMWPE particles. Bio-Medical Materials and Engineering, vol. 10, pp.229-240. 2000.
Jin Z; Ingham E; Fisher J Frictional behaviour of bovine articular cartilage. Biorheology, vol. 37, pp.57-63. 2000.
Korossis S; Ingham E; Fisher J Cardiac valve replacement: A bioengineering approach. Bio-Medical Materials and Engineering, vol. 10, pp.83-124. 2000.
Jin ZM; Firkins P; Farrar R; Fisher J Analysis and modelling of wear of cobalt-chrome alloys in a pin-on-plate test for a metal-on-metal total hip replacement. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 214, pp.559-568. 2000.
McNie C; Barton DC; Ingham E; Tipper JL; Fisher J; Stone MH The prediction of polyethylene wear rate and debris morphology produced by microscopic asperities on femoral heads. Journal of Materials Science: Materials in Medicine, vol. 11, pp.163-174. 2000.
Streicher RM; Fisher J Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically. Journal of Arthroplasty, vol. 15, pp.793-795. 2000.
Fisher J Production of TNF-alpha and bone resorbing activity by macrophages in response to different types of bone cement. Biomaterials, vol. 21, pp.1005-1013. 2000.
Jones VC; Barton DC; Fitzpatrick DP; Auger DD; Stone MH; Fisher J An Experimental Model of Tibial Counterface Polyethylene Wear in Mobile Bearing Knees : The Influence of Design and Kinematics. Biomedical Engineering, vol. 9, pp.189-196. 1999.
Ingham E; Wroblewski B; Fisher J; Tipper JL Analysis of debris from brushing the femoral canal with a plastic brush - a potential cause of loosening in total hip. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 213, pp.503-506. 1999.
Matthews JB; Fisher J The influence of lubricant on the morphology of ultra-high molecular weight polyethylene wear debris generated in. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 213, pp.155-158. 1999.
Fisher J; Wroblewski B Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses. Journal of Materials Science: Materials in Medicine, vol. 11, pp.117-124. 1999.
Fisher J Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses. Biomaterials, vol. 20, pp.1833-1840. 1999.
Fisher J Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in. Journal of Materials Science: Materials in Medicine, vol. 10, pp.353-362. 1999.
Nagy ZL; Fisher J; Walker PG; Watterson KG The effect of sizing on the in vitro hydrodynamic characteristics and leaflet motion of the Toronto SPV stentless valve. The Journal of Thoracic and Cardiovascular Surgery, vol. 117, pp.92-98. 1999.
McNie C; Barton DC; Stone MH; Fisher J Prediction of plastic strains in ultra-high molecular weight polyethylen due to microscopic asperity interactions during sliding wear. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 212, pp.49-56. 1998.
Wroblewski B; Fisher J Quantitative Comparison of Wear Debris from UHMWPE that has and has not been Sterilised by Gamma Irradiation. Journal of Bone and Joint Surgery: American Volume, vol. 80B, pp.340-344. 1998.
Reeves EA; Barton DC; Fitzpatrick DP; Fisher J A Two-Dimensional Model of Cyclic Strain Accumulation in Ultra-High Molecular Weight Polyethylene Knee Replacements. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 212, pp.189-198. 1998.
Fisher J Wear of Ultra-High Molecular Weight Polyethylene against Damaged and Undamaged Stainless Steel and Diamond-like Carbon-coated Counterfaces. Journal of Materials Science: Materials in Medicine, vol. 9, pp.597-601. 1998.
Bigsby RJA; Auger DD; Jin Z; Dowson D; Hardaker C; Fisher J A Comparative Tribological Study of the Wear of Composite Cushion Cups in a Physiological Hip Joint Simulator. Journal of Biomechanics, vol. 31, pp.363-369. 1998.
Wroblewski B; Fisher J Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head. Journal of Bone and Joint Surgery: British Volume, vol. 80B, pp.894-899. 1998.
Jin Z; Dowson D; Fisher J; Ohtsuki N; Murakami T; Higaki H; Moriyama S Prediction of Transient Lubricating Film Thickness in Knee Prostheses with Compliant Layers. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 212, pp.157-164. 1998.
Fisher J Effect of Counterface Surface Roughness and its Evolution on the Wear and Friction of PEEK and PEEK-bonded Carbon Fibre Composites on Stainless Steel. Wear, vol. 217, pp.177-182. 1998.
Fisher J Wear of ultra high molecular weight polyethylene in total hip joints. Biological and mechanical micro mechanism. Actualites en Biomateriaux, vol. 4, pp.29-42. 1998.
Marrs H; Barton DC; Doyle C; Jones RA; Ward IM; Fisher J Comparative wear under four different tribological conditions of acetylene crosslinked ultra high molecular weight polyethylene. Journal of Materials Science, 1998.
Fisher J Investigation into the Effect of Proteoglycan Molecules on the Tribological Properties of Cartilage Joint Tissues. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 21, pp.177-182. 1998.
Fisher J; Wroblewski B Polyethylene particles of a critical size are necessary for the induction of cytokines by macrophages in vitro.. Biomaterials, vol. 19, pp.2297-2302. 1998.
Fisher J Wear of Polyethylene in Artificial Hip Joints: Superolaterial Wear of the Acetabulum. Journal of Bone and Joint Surgery: American Volume, vol. 80B, pp.190-191. 1998.
Stewart TD; Jin Z; Fisher J Analysis of Contact Mechanics for Composite Cushion Knee Joint Replacements. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 212, pp.1-10. 1998.
Barbour PSM; Barton DC; Fisher J The influence of contact stress on the wear of UHMWPE for joint replacements.. Journal of Materials Science: Materials in Medicine, vol. 8, pp.603-611. 1997.
Besong A; Hailey JL; Ingham E; Stone MH; Wroblewski B; Fisher J A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of. Biomaterials, vol. 7, pp.56-65. 1997.
Fisher J; Issac GH Comparison of wear of aged and non-aged UHMWPE sterilised by gamma irradiaton and gas plasma. Journal of Materials Science: Materials in Medicine, vol. 8, pp.275-378. 1997.
Fisher J Wear of ultra high molecular weight polyethylene in artificial joints: a new approach to the quantification of wear debris.. Materials & Design, vol. 3, pp.543-548. 1997.
Hedia HS; Barton DC; Fisher J Material Optimisation of the Femoral Component of a Hip Prosthesis based on the Fatigue Notch Factor Approach. Bio-Medical Materials and Engineering, vol. 7, pp.83-98. 1997.
Stewart TD; Jin Z; Fisher J Friction of composite cushion bearings for total knee joint replacements under adverse lubrication conditions. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 211H, pp.451-465. 1997.
Fisher J; Watterson KG The influence of sizing and method of fixation on the hydrodynamic function of stentless free hand inserted porcine bioprostheses. The Journal of Heart Valve Disease, vol. 6, pp.433-438. 1997.
Jin Z; Dowson D; Fisher J; Ohtsuki N; Murakami T; Moriyama S; Higaki H Prediction of lubricating film thickness in knee prostheses with compliant layers.. Proceedings of Japanese Society of Mechanical Engineers, vol. 205, pp.239-240. 1997.
Hardaker C; Fisher J Wear of UHMWPE in physiological anatomical hip joint simulator. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 211H, pp.265-269. 1997.
Fisher J; Watterson KG The influence of free hand suturing rechnique and zero pressure fixation on hydrodynamic function of aortic root and aortic valve leaflets. European Journal of Cardio-Thoracic Surgery, vol. 11, pp.280-286. 1997.
Hedia HS; Barton DC; Fisher J; Elmidany TT A method for shape optimisation of a hip prosthesis to maximise the fatigue life of the cement. Medical Engineering & Physics, vol. 18, pp.647-654. 1996.
Jin Z; Fisher J Determination of lubricating film thickness for permeable hydrogel and non-permeable polyurethane layers bonded to a rigid substrate.. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 210, pp.89-93. 1996.
Fisher J The influence of loading time and lubricant on the frictino of articular cartilage.. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. H, pp.109-119. 1996.
King MJ; Corden J; David T; Fisher J A three dimensional, time dependent analysis of flow through a bileaflet mechanical heart valve: Comparison of experimental and numerical results. Journal of Biomechanics, vol. 29, pp.609-618. 1996.
Hedia HS; Barton DC; Fisher J; Ibrahim A Shape optimisation of a Charnley prosthesis based on the fatigue notch factor.. Bio-Medical Materials and Engineering, vol. 6, pp.199-218. 1996.
Fisher J; Barton DC A biomechanical study of burst fractures. Journal of Bone and Joint Surgery: British Volume, vol. 78B, 1996.
Fisher J Finite element stress analysis of a new design of synthetic leaflet heart valves.. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 210, pp.267-272. 1996.
King MJ; Olin CL; Fisher J An initial investigation into the wear and damage of three types of heart valve.. The Journal of Heart Valve Disease, vol. 5, pp.5111-5114. 1996.
Wroblewski B; Fisher J UHMWPE wear debris generated invivo and in laboratory tests; the influence of counterface roughness. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 210, pp.3-10. 1996.
David T; Fisher J The influence of open leaflet geometry on the haemodynamic flow characterisation of the polyurethane trileaflet valve. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 210, pp.273-285. 1996.
Hedia HS; Barton DC; Fisher J; Elmidany TT Effect of FE idealisation, load and interface in the stress distribution and fatigue match factor in the human femur.. Bio-Medical Materials and Engineering, vol. 6, pp.135-152. 1996.
Barton DC; Fisher J Neurological injury in thoracolumbar burst fracture - a biomedical study. British Orthopaedic Association Spring Meeting, 1996.
David T; Fisher J Determination of the curvatures and bending strains in open trileaflet heart valves. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 209, pp.121-128. 1995.
David T; Fisher J In vitro determination of the curvatures and bending strains acting on the leaflets of polyurethane trileaflet heart valves during leaflet motion. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 209, pp.243-253. 1995.
Jin Z; Dowson D; Fisher J; Rimmer D; Wilkinson R; Jobbins B Measurement of lubricating film thickness in low elastic modulus lined bearings, with particular reference to models of cushion form bearings for total joint replacements. Part 1: Steady state entraining motion. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, vol. 208J, pp.207-212. 1994.
King MJ; David T; Fisher J An initial parametric study on fluid flow through bi-leaflet mechanical heart valves, using computational fluid dynamics. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 208(H), pp.63-72. 1994.
Jin Z; Dowson D; Fisher J Minimum and central film thickness formulae for an elastic layer firmly bonded to a rigid cylindrical substrate under entraining action. Wear, vol. 170, pp.281-284. 1993.
Auger DD; Dowson D; Fisher J Friction of cylindrical cushion form bearings for artificial joints - a comparison of theory and experiment. Tribology Series, vol. 25, pp.683-692. 1993.
Cooper JR; Dowson D; Fisher J Macrosopic and microscopic wear mechanisms in UHMWPE. Wear, vol. 162, pp.378-384. 1993.
Auger DD; Dowson D; Fisher J; Jin Z Friction and lubrication in cushion form bearings for artificial hip joints. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 207, H1, pp.25-33. 1993.
Jin Z; Dowson D; Fisher J Wear and friction of medical grade polyurethane sliding on smooth metal counterfaces. Wear, vol. 162-164, pp.627-630. 1993.
Jin Z; Dowson D; Fisher J The effect of porosity of articular cartilage on the lubrication of a normal hip joint. Proceedings of the Institution of Mechanical Engineers. Part H, Engineering in Medicine, vol. 206H, pp.117-124. 1992.
Cooper JR; Dowson D; Fisher J Mechanisms of the generation of wear particles of UHMWPE. Tribology Series, vol. 21, pp.29-40. 1992.
Cooper JR; Dowson D; Fisher J Birefringent studies of polyethylene wear specimens and acetabular cups. Wear, vol. 151, pp.391-402. 1991.
Fisher J; Dowson D Tribology of total artificial joints. Proceedings of the Institution of Mechanical Engineers. Part C: Mechanical Engineering Science, vol. 412, pp.73-79. 1991.
Cooper JR; Dowson D; Fisher J; Jobbins B Ceramic bearing surfaces in total artificial joints: resistance to third body wear damage from bone cement particles. Journal of Medical Engineering & Technology, vol. 15, pp.63-67. 1991.

Conference Proceedings

Tatterton M; Wilshaw SP; Berry H; Kearney JN; Fisher J; Ingham E; Homer-Vanniasinkam S Tissue engineering small-diameter vascular grafts: decellularisation of porcine arteries in: BRITISH JOURNAL OF SURGERY, vol. 99, pp.11-11. 2012.LINK
Luo J; Korossis SA; Fisher J; Ingham E Production and characterisation of low concentration SDS decellularised porcine pulmonary valvular conduits in: JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, vol. 6, pp.114-114. 2012.LINK
Hasan J; Jones GL; Stanley MJ; Fisher J; Ingham E Development of a tissue engineered meniscal replacement in: JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, vol. 6, pp.47-47. 2012.LINK
Senior RA; Plainfosse M; Crawford A; Williams S; Jin ZM; Fisher J; Hatton PV Increased viscosity media for use in bioreactor culture to prepare tissue engineered cartilage constructs for tribo-mechanical testing in: JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, vol. 6, pp.71-72. 2012.LINK
Fermor HL; McLure SWD; Taylor SD; Russell SL; Williams S; Fisher J; Ingham E Biological, biochemical and biomechanical characterisation of cartilage from the porcine, bovine and ovine hip and knee in: JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, vol. 6, pp.66-66. 2012.LINK
Taylor C; Russell S; Fisher J; Ingham E; Tipper J Development and characterization of an in vitro model of cartilage degeneration in: JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, vol. 6, pp.66-67. 2012.LINK
Girn HRS; Turner E; Fisher J; Homer-Vanniasinkam S 1H-NMR-based metabolomics: a novel biomarker approach to peripheral arterial disease (PAD) in: BRITISH JOURNAL OF SURGERY, vol. 97, pp.3-3. 2010.
Yan Y; Neville A; Dowson D; Fisher J; Williams S Effect of Corrosion and Biofilm on Friction Behavior in Biotribocorrosion System for Metal-on-Metal Hip Prosthesis in: Luo JB; Meng YG; Shao TM; Zhao Q (editors) ADVANCED TRIBOLOGY, pp.829-830. 2009.
Kang L; Lewis E; Mohanraj J; Brown T; Barton D; Jin ZM; Fisher J The Molecular Orientation Induced by Multi-Directional Sliding in the UHMWPE Used for the Artificial Joint Replacements in: Luo JB; Meng YG; Shao TM; Zhao Q (editors) ADVANCED TRIBOLOGY, pp.837-838. 2009.
Quinonez AF; Fisher J; Jin ZM Radial Displacements in a Thin Semi-Spherical Layer of Biphasic Articular Cartilage for Use in EHL Models of Natural Hip Joints in: Luo JB; Meng YG; Shao TM; Zhao Q (editors) ADVANCED TRIBOLOGY, pp.839-840. 2009.
Ellison P; Barton DC; Jin ZM; Fisher J A New Method to Simulate Wear within the Patellofemoral Joint of TKR in: Luo JB; Meng YG; Shao TM; Zhao Q (editors) ADVANCED TRIBOLOGY, pp.863-864. 2009.
Luo Y; Ge S; Jin Z; Fisher J; Mischler S EFFECT OF SURFACE MODIFICATION ON SURFACE PROPERTIES AND TRIBOLOGICAL BEHAVIOURS OF TITANIUM ALLOYS in: P I MECH ENG J-J ENG, vol. 223, pp.605-605. 2009.
Yan Y; Neville A; Dowson D; Williams S; Fisher J; Medley JB THE INFLUENCE OF SWING PHASE LOAD ON THE ELECTROCHEMICAL RESPONSE, FRICTION, AND ION RELEASE OF METAL-ON-METAL HIP PROSTHESES IN A FRICTION SIMULATOR in: P I MECH ENG J-J ENG, vol. 223, pp.604-604. 2009.
Plainfosse M; Crawford A; Hatton PV; Jin ZM; Fisher J Biological and frictional properties of tissue engineered cartilage cultured using bioreactors in: INTERNATIONAL JOURNAL OF EXPERIMENTAL PATHOLOGY, vol. 90, pp.A110-A110. 2009.
Wang L; Wilshaw SP; Korossis S; Fisher J; Jin Z; Ingham E Factors Influencing the Oxygen Consumption Rate of Aortic Valve Interstitial Cells: Application to Tissue Engineering. in: Tissue Eng Part A. 2009.DOI
Wang L; Wilshaw S; Korossis S; Fisher J; Jin ZM; Ingham E Measurement of oxygen consumption rate for aortic valve interstitial cells (VICs): Application to tissue engineering in: TISSUE ENGINEERING PART A, vol. 14, pp.877-877. 2008.
Wilshaw SP; Aggeli A; Fisher J; Ingham E The biocompatibility and immunogenicity of self-assembling peptides for use in tissue engineering and regenerative applications in: TISSUE ENGINEERING PART A, vol. 14, pp.785-785. 2008.
Stapleton TW; Ingram J; Fisher J; Ingham E Biocompatibility of an acellular porcine meniscal scaffold in: TISSUE ENG PT A, vol. 14, pp.812-812. 2008.
Plainfosse M; Hatton PV; Crawford A; Katta J; Jin ZM; Fisher J Frictional properties of tissue engineered cartilage generated using standard or bioreactor culture in: TISSUE ENGINEERING PART A, vol. 14, pp.737-737. 2008.
Yan Y; Neville A; Dowson D; Williams S; Fisher J Tribo-corrosion analysis of wear and metal ion release interactions from metal-on-metal and ceramic-on-metal contacts for the application in artificial hip prostheses in: P I MECH ENG J-J ENG, vol. 222, pp.483-492. 2008.
Brockett CL; Williams S; Jin ZM; Isaac G; Fisher J A comparison of friction in 28 mm conventional and 55 mm resurfacing metal-on-metal hip replacements in: P I MECH ENG J-J ENG, vol. 221, pp.461-461. 2007.
Bolland F; Korossis S; Ingham E; Fisher J; Kearney JN; Southgate J Functional tissue-engineering of the urinary bladder in: TISSUE ENG, vol. 13, pp.1698-1699. 2007.
Plainfosse M; Hatton PV; Crawford A; Katta J; Jin Z; Fisher J Influence of the extracellular matrix on the mechanical properties of tissue engineered cartilage in: INTERNATIONAL JOURNAL OF EXPERIMENTAL PATHOLOGY, vol. 88, pp.A87-A87. 2007.
Pawaskar SS; Jin ZM; Fisher J Modelling of fluid support inside articular cartilage during sliding in: P I MECH ENG J-J ENG, vol. 221, pp.455-455. 2007.
Katta J; Pawaskar SS; Jin ZM; Ingham E; Fisher J Effect of load variation on the friction properties of articular cartilage in: P I MECH ENG J-J ENG, vol. 221, pp.455-455. 2007.
Tiller JL; Galvin AL; Ingham E; Fisher J Estimation of the osteolytic potential of noncrosslinked and crosslinked polyethylenes and ceramic-on-ceramic total hip prostheses in: AM SOC TEST MATER, vol. 1472, pp.75-90. 2006.
Kang L; Galvin AL; Jin Z; Fisher J Modelling the effect of head diameter and cup wall thickness on contact mechanics and wear of cross-linked UHMWPE cups in: Proceedings of WTC2005 World Tribology Congress III September 12-16, 2005, Washington, D.C., USA. ASME. 2005.
Wang F; Galvin AL; Jin Z; Ingham E; Fisher J An integrated experimental and theoretical contact mechanics study of UHMWPE hip implants tested in a hip simulator in: Proceedings of WTC2005 World Tribology Congress III September 12-16, 2005, Washington, D.C., USA. ASME. 2005.
Galvin AL; Ingham E; Fisher J Wear of crosslinked UHMWPE in a hip joint simulator in: Proceedings of WTC2005 World Tribology Congress III September 12-16, 2005, Washington, D.C., USA. ASME. 2005.
Williams S; Jin Z; Stone MH; Ingham E; Fisher J The effect of different lubrication on regimes and lubricants on the friction hard-on-hard total hip replacements in: Proceedings of WTC2005 World Tribology Congress III September 12-16, 2005, Washington, D.C., USA. ASME. 2005.
Northwood EJ; Kowalski R; Fisher J An In-Vitro Investigation of Sliding Friction between Biomaterials for Cartilage Substitution and Articular Cartilage in: ASME (editors) Proceedings of WTC2005 World Tribology Congress III September 12-16, 2005, Washington, D.C., USA. 2005.
Afsharpoya B; Stewart TD; Barton DC; Fisher J; Purbach B; Wroblewski M Analysis of cement mantle stress with the combination of proximal cement/bone debonding and distal implant/cement debonding under conditions modelling retroversion torque at heel-strike in: Proc. Computer methods in Biomechanics & Biomedical Engineering, Madrid 2004. 2004.
Bell CJ; Carrick LM; Ingham E; Aggeli A; Boden N; Waigh TA; Fisher J Self-assembling peptide nanomaterials as injectable lubricants for osteoarthritis in: 5th Symposium of the International Cartilage Repair Society, pp.27-30. Medimond. 2004.
Fisher J; Nevelos J; Stewart TD; Tipper JL; Ingham E Long term wear of ceramic on ceramic hips in: 9th BIOLOX Symposium, pp.45-46. 2004.
Pina CF; Dahm KL; Fisher J; Dearnley PA Characteristics and corrosion-wear response of S-phase coated ortron 90 in: TRIBOLOGY S, vol. 43, pp.815-824. 2004.
Graindorge S; Jin Z; Fisher J; Twigg P; Grant C; Ingham E; Mitchell W Biphasic amorpohous surface layer lubrication of articular cartilage - dynamic loading response in: Proceedings of 4th International Biotribology Forum & 24th Biotribology Symposium, Kyushu University, Japan.. 2003.
Fisher J; Stone MH; Ingham E Wear of ultra high molecular weight polyethylene. UHMWPE for arthroplasty : past, present and future in: Centro Traumatologico Ortopedico, Turin Italy.. 2003.
Kamali A; Farrar R; Hatto P; Stone MH; Fisher J Reduction of UHMWPE wear in artificial knee joints by titanium nitride coatings in: Proceedings of 16th Annual Symposium of the International Society for Technology in Athroplasty, San Francisco USA, vol. 1, pp.274-279. 2003.
Stewart TD; Williams S; Tipper JL; Ingham E; Stone MH; Fisher J Advances in simulator testing of orthopaedic joint prostheses in: Dowson; D; Priest; M; Dlamaz; G (editors) Proceedings of the 29th Leeds-Lyon Symposium on Tribology, 3-6 Sept 2002, vol. Tribology Series, 41, pp.291-296. Elsevier. 2003.
Forsey RW; Ingham E; Fisher J; Bell C; Thompson J; Stone MH A comparison study of the effect of novel hyaluronic acid (HA) based therapeutic lubricants on friction levels of osteoarthritic damaged human cartilage in: ANNALS OF THE RHEUMATIC DISEASES, vol. 62, pp.276-276. 2003.
Stewart TD; Tipper JL; Insley GM; Streicher RM; Ingham E; Fisher J Wear of alumina matrix composite ceramics for hip prostheses in: Proceedings of the 16th Annual Symposium of the International Society for Technology in Arthroplasty, San Francisco USA, pp.125-131. 2003.
D'Souza SS; Butterfield M; Fisher J Kinematics of synthetic flexible leaflet heart valves during accelerated testing in: J HEART VALVE DIS, vol. 12, pp.110-119. 2003.
Williams S; Tipper JL; Hu XQ; Stone MH; Ingham E; Isaac GH; Hatto P; Fisher J The influence of swing phase loading on wear of metal-on-metal and Crn surface modified total hip replacements in: Proceedings of the 16th Annual Symposium of the International Society for Technology in Arthroplasty, San Francisco USA, pp.143-149. 2003.
Wirza R; Bloor MS; Fisher J Inspection strategies for complex curved surfaces using CMM in: Sloot P; Tan CJK; Dongarra JJ; Hoekstra AG (editors) COMPUTATIONAL SCIENCE-ICCS 2002, PT III, PROCEEDINGS, vol. 2331, pp.184-193. 2002.
Jennings LM; Butterfield M; Booth C; Watterson KG; Fisher J The pulmonary bioprosthetic heart valve: its unsuitability for use as an aortic valve replacement. in: J Heart Valve Dis, vol. 11, pp.668-678. 2002.LINK
Hanson BM; Fisher J Rheology of acrylic bone cement with additional antibiotics in: British Orthopaedic Research Society Meeting. 2001.
Hanson BM; Fisher J Development of a rheometer for in-situ measurement of viscoelastic properties of acrylic bone cement during curing in: European Society for Biomaterials Annual Meeting 2001. 2001.
Hanson BM; Brown MD; Fisher J Self sensing: Closed-loop estimation for a linear electromagnetic actuator in: P AMER CONTR CONF, pp.1650-1655. 2001.
McEwen HMJ; Fisher J; Goldsmith AAJ; Auger DD; Hardaker C; Stone MH Wear of fixed bearing and rotating platform mobile bearing knees subjected to high levels of internal and external tibial rotation in: JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, vol. 12, pp.1049-1052. 2001.
Roy BR; Nevelos AB; Ingham E; Shaw DL; Fisher J Comparison of ceramic on ceramic to ceramic on polyethylene total hip replacement in: Giannini S; Moroni A (editors) BIOCERAMICS, vol. 192-1, pp.991-994. 2000.
Nevelos J; Ingham E; Doyle C; Streicher R; Nevelos A; Fisher J Micro-separation in vitro produces clinically relevant wear of ceramic-ceramic total hip replacements in: Giannini S; Moroni A (editors) BIOCERAMICS, vol. 192-1, pp.529-532. 2000.
Reid SA; Walker PG; Fisher J; Nagy Z; Ridgway JP; Watterson K; Sivananthan M Pulmonary valve quantification using MRI in patients with congenital aortic valve disease. in: Enderle JD (editors) PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, vol. 22, pp.676-677. 2000.
Walker PG; Watterson KG; Fisher J Pulmonary valve function using breath-hold MRI phase velocity mapping in: IPEMB. Brighton. 1998.
David T; Fisher J Complex Time Dependent Flow in the Neighbourhood of the Aortic Root in: 3rd World Congress of Biomechanics, pp.23. Sapporo. 1998.
Fisher J; Butterfield M; Revanna P; Nagy ZL; Walker PG; Watterson KG Invitro testing of free sewn aortic bioprotheses "A tissue host root model" in: Workshop on Prosthetic Heart Valves: Future Technologies. Sea Pines Plantation. 1998.
Fisher J Investigation into the effect of glycoproteins and phospholipids on the friction of articular cartilage in: Proceedings of Japanese Society of Mechanical Engineers, vol. 205, pp.229-230. 1997.
Fisher J; Wroblewski B Wear of UHMWPE in artificial joints. A new approach to quantificatin of wear debris in: Proc. EUROMAT, pp.543-545. 1997.
David T; Fisher J Time Dependent flow in the aortic arch with and without bi-leaflet prostheses in: ASME Bioengineering Conference, vol. 1, . ASME. 1997.
Stewart TD; Jin Z; Fisher J Friction in "cushion form bearing" for total knee joint replacements under adverse lubricating conditions in: Proceedings of Japanese Society of Mechanical Engineers, vol. 205, pp.241-242. 1997.
Barton DC; Fisher J Prediction of cyclic strain accumulation of UHMWPE in knee replacements in: First World Tribology Congress. 1997.
Barton DC; Fisher J A time dependent analysis of cyclic strain accumulation in UHMWPE knee replacements in: 43rd Orthopaedic Research Society Annual Meeting. San Francisco. 1997.
Fisher J Investigation into the effect of acetabular tissue on the performance of the bipolar hip prostheses. in: Proceedings of Japanese Society of Mechanical Engineers, vol. 205, pp.451-452. 1997.
Barton DC; Fisher J Parametric optimization of the materials of a Charnley hip prostheses to minimise stress shielding in the proximal bone whilst maximising the fatigue life of the cement in: 5th World Biomaterials Congress. 1996.
David T; Fisher J An Investigation into the Effect of Leaflet Opening on the Fluid Flow past a Bileaflet Mechanical Heart Valve in: BIOMED 93 2nd International Conference on Computers in Biomedicine 1993, pp.117-124. Computational Mechanics Publications Southampton. 1994.
Caravia L; Dowson D; Fisher J; Corkhill PH; Tighe BJ Friction and mixed lubrication in soft layer contacts. in: 19th Leeds-Lyon Symposium on Tribology, vol. 25, pp.529-534. Elsevier. 1993.

Book Chapters

Fisher J Tribology of Hip Prostheses in: Knahr K (ed.) Tribology in Total Hip Arthroplasty, pp.3-9. Springer Verlag. 2011.
Fisher J; Jin Z; Ingham E; Jennings L; Tipper J; Williams S Bearings: Tribological Aspects: To Wear or Not to Wear in: Vidalain J-P; Si Selmi T; Beverland D; Young S; Board T; Boldt J; Brumby S (ed.) The Corail Hip System: A practical approach based on 25 years of experience, pp.218-223. Springer Verlag. 2011.
Brockett CL; Fisher J Experimental wear studies of total joint replacements in: Davim JP (ed.) Biotribology, pp.51-86. ISTE Ltd. 2010.
Jin Z; Fisher J Tribology in joint replacements in: Revell PA (ed.) Joint Replacement Technology, pp.31-55. Woodhead Publishing Ltd. 2008.
Fisher J Wear of joint replacements in: Eds SA; Rubash HE; Jacobs JJ (ed.) Joint Replacement and Bone Resorption – Pathology, Biomaterials and Clinical Practice, pp.145-169. Joint Replacement and Bone Resorption – Pathology, Biomaterials and Clinical Practice. 2006.
Jennings LM; Fisher J; Stewart TD; Masson B; Lazennec JY Wear simulator study of the tripolar all ceramic hip prosthesis in: Benazzo F; Falez F; Dietrich M (ed.) Bioceramics and Alternative Bearings in Joint Arthroplasty, pp.307-308. Steinkopff Verlag, Darmstadt. 2006.
Jin Z; Tipper JL; Stone MH; Ingham E; Fisher J Hip Joints, Artificial in: Webster JG (ed.) Encyclopedia of Medical Devices and Instrumentation, pp.514-525. John Wiley & Sons Inc. 2006.
Fisher J; Jennings LM; Galvin AL Wear of highly crosslinked polyethylene against cobalt chrome and ceramic femoral heads in: , pp.185-188. 2006.
Jin Z; Fisher J; Ingham E Biotribology: Material Design, Lubrication and Wear in Artificial Hip Joints in: Totten GE (ed.) CRC Handbook of Lubrication - Theory and Practice of Tribology: Volume 1 -Application and Maintenance, pp.1-24. Taylor & Francis. 2006.
Lazennec JY; Jennings LM; Fisher J; Masson B Two ceramic bearing surfaces with a self adjusting cup: A new application of delta ceramics to reduce the risk of dislocation and subluxation. in: Antionio EJAD; Dietrich M (ed.) New Developments in the Basic Science of Ceramics and Other Alternative Bearings, pp.61-66. New Developments in the Basic Science of Ceramics and Other Alternative Bearings. 2005.
Fisher J; Galvin AL; Tipper JL; Stewart TD; Stone MH; Ingham E Comparison of the functional biological activity and osteolytic potential of ceramic on ceramic and cross linked polyethylene bearings in the hip in: Antionio EJAD; Dietrich M (ed.) New Developments in the Basic Science of Ceramics and Other Alternative Bearings, pp.21-24. New Developments in the Basic Science of Ceramics and Other Alternative Bearings. 2005.
Fisher J; Firkins P; Tipper JL; Farrar R; Ingham E Wear of a novel ceramic on metal bearings for hip prosthesis in: Antionio EJAD; Dietrich M (ed.) New Developments in the Basic Science of Ceramics and Other Alternative Bearings, pp.197-199. New Developments in the Basic Science of Ceramics and Other Alternative Bearings. 2005.
Korossis S; Bolland F; Kearney JN; Fisher J; Ingham E Bioreactors in tissue engineering in: Ashammakhi N; Reis RL (ed.) Topics in Tissue Engineering, vol. 2, pp.2-23. Topics in Tissue Engineering. 2005.LINK
Fisher J; Ingham E Wear Debris in: Bowlin GWGL (ed.) Encyclopedia of Biomaterials and Biomedical Engineering, pp.1772-1779. Marcel Dekker. 2004.
Figueiredo Pina CG; Dahm KL; Fisher J; Dearnley PA Characteristics and corrosion-wear response of s-phase coated ortron 90 in: al GDE (ed.) Transient Processes in Tribology, pp.814-824. Elsevier B. V.. 2004.
Tipper JL; Matthews JB; Ingham E; Stewart TD; Fisher J; Stone MH Wear and functional biological activity of wear debris generated from UHMWPE-on-Zirconia ceramic, metal-on-metal, and alumina ceramic-on-ceramic hip prostheses during hip simulator testing in: , pp.7-28. 2003.
Stewart TD; Tipper JL; Stone MH; Ingham E; Fisher J Wear of polyethylene against scratched metallic femoral heads in hip prostheses in: Garino J; Willamann G (ed.) Bioceramics in Joint Arthroplasty, pp.31-33. Georg Thieme Verlag, Stuttgart. 2002.
McEwen H; McNulty DE; Auger DD; Farrar R; Liao YS; Stone MH; Fisher J Wear analysis of mobile bearing knee in: Hamelynck S (ed.) LCS Mobile Bearing Knee Arthroplasty - A 25 years worldwide review, pp.67-73. LCS Mobile Bearing Knee Arthroplasty - A 25 years worldwide review. 2002.
Insley GM; Stewart TD; Nevelos JE; Fisher J; Streicher RM Wear of ceramic-on-ceramic hip prostheses under microseparation simulation conditions in: Hutchings IM (ed.) Friction, lubrication and wear of artificial joints., pp.89-98. Professional Engineering Publishing. 2002.LINK
Walker PG; Fisher J; Nagy ZL; Watterson KG The importance of slice location on the quantification of pulmonary valve hemodynamics using magnetic resonance imaging in patinets with congenital aortic valve disease. in: Magnetic Resonance Materials in Physics, Biology and Medicine. London, England.. 1999.
Fisher J; Jasty M; McKellop HA Roundtable Discussion : Polyethylene Wear in Total Joint Arthroplasty in: Orthopaedics Today, pp.35-52. Orthopaedics Today. 1998.
Fisher J; Watterson KG Comparative Mechanics of Pulmonary and Aortic Porcine Bisprosthetic Valve Leaflets in: Gabbay S; MD DJW (ed.) Advances in Anticalcific and Antidegenerative Treatment of Heart Valve Bioprostheses, pp.61-69. Advances in Anticalcific and Antidegenerative Treatment of Heart Valve Bioprostheses. 1998.
Lancaster JG; Dowson D; Fisher J The Wear of Ultra High Molecular Weight Polyethylene Sliding on Metallic and Ceramic Counterfaces Representative of Current Femoral Surfaces in Joint Replacement in: Advances in Medical Engineering, Editor D Dowson, pp.109-116. The Institution of Mechanical Engineers. 1998.
Fisher J Tribology of natural and artificial joints. in: Hughes S; McCarthey I (ed.) Sciences Basic to Orthopaedics, pp.240-249. London. 1997.
Fisher J How to reduce polyethylene wear in: Implant Special, pp.17-18. Springer Verlag, Heidelberg. 1997.
Barton DC; Fisher J Stress analysis of microscopic wear of UHMWPE in artificial joints in: European Orthopaedic Research Society Meeting. European Orthopaedic Research Society Meeting. 1997.
Forster H; Fisher J; Dowson D; Wright V The effect of stationary loading on the friction and boundary lubrication of articular cartilage in the mixed lubrication regime in: Dowson D (ed.) Lubricants and Lubrication, pp.71-84. Elsevier Science Publishers BV. 1995.
Caravia L; Dowson D; Fisher J; Corkhill PH; Tighe BJ Sliding friction in porous and non porous elastic layers: The effect of translation of the contact zone over the porous material in: Dowson D (ed.) Proceedings of the 20th Leeds-Lyon Symposium on Tribology, In Dissipative Processes in Tribology, pp.261-264. Elsevier Science Amsterdam. 1994.

Internet Publications

Fisher J Surgery for arthritis - Total hip and knee joint replacement, . None. . 2004.LINK

Patents

Ingham E; Fisher J; Stapleton T; Ingram J A cellular porcine meniscus for meniscal repair/replacement. 2008.
Fisher J; Ingham E; Booth C Decellularisation of tissue implant material. 2002.

Other

Fisher J 50 Active Years After 50. NIHR Office for Clinical Research Infrastructure (NOCRI). London, 2011.
Fisher J; Zolfagharifard E Interview with J Fisher - Rolling back the Years. 2011.

Staff and students list