Al-Hajjar M, Leslie IJ, Tipper J, Williams S, Fisher J, Jennings LM. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic-on-ceramic total hip replacement. J Biomed Mater Res B Appl Biomater 95(2):263-268, November 2010

Brockett C, Fisher J. Chp 2 Experimental wear studies of total joint replacements. Biotribology, Editor J Paulo Davim ISBN 978-1-84821-275-6. Publisher ISTE/J Wiley & Sons Ltd, 2010

Cunningham E, Dunne N, Walker G, Maggs C, Wilcox R, Buchanan F. Hydroxyapatite bone substitutes developed via replication of natural marine sponges. 29th Northern Ireland Biomedical Engineering Conference, Queens Univ Belfast, Belfast, NORTH IRELAND, 08 Apr 2009. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE. SPRINGER. 21: 2255-2261, August 2010

Figgitt M, Newson R, Leslie IJ, Fisher J, Ingham E, Case. The genotoxicity of physiological concentrations of chromium (Cr(III) and Cr(VI)) and cobalt (Co(II)): An in vitro study. Mutation Research/Fundamental and Molecular Mechanisms of Mutagenesis (MUTAT RES-FUND MOL M) 688(1-2):53-61, June 2010

Ellison P, Fisher J. Assessment of the damage in retrieved patellar components. J Long Term Eff Med Implants 20(1):57-72, 2010

Fisher J, Ingham E, Wilshaw S. ACELLULAR VASCULAR PRODUCTS. Patent number: GB1020846.0 (United Kingdom). Application number: LPB/P124293GB. Status: Submitted. Filed date: 09 December 2010

Fisher J, Jennings LM, Galvin AL, Jin ZM, Stone MH, Ingham E. 2009 Knee Society Presidential Guest Lecture: Polyethylene wear in total knees. Clinical Orthopaedics and Related Research, vol. 468, pp.12-18, 2010

Galvin AL, Jennings LM, Tipper JL, Ingham E, Fisher J. Wear and creep of highly crosslinked polyethylene against cobalt chrome and ceramic femoral heads. P I MECH ENG H 224(H10):1175-1183, 2010

Gao LM, Meng QE, Liu F, Fisher J, Jin ZM. The effect of aspherical geometry and surface texturing on the elastohydrodynamic lubrication of metal-on-metal hip prostheses under physiological loading and motions. P I MECH ENG C-J MEC 224(C12):2627-2636, 2010

Gao LM, Meng QE, Wang FC, Yang PR, Jin ZM. Numerical solutions for the elastic deformation of spherical bearing surfaces of metal-on-metal hip joint implants. P I MECH ENG J-J ENG 224(J8):797-805, 2010

Gao LM, Yang PR, Dymond I, Fisher J, Jin ZM. Effect of surface texturing on the elastohydrodynamic lubrication analysis of metal-on-metal hip implants. 36th Leeds-Lyon Symposium on Multi-Facets of Tribology, Inst Natl Sci Appliquees, Lyon, FRANCE, 01 Sep 2009 - 03 Sep 2009. TRIBOLOGY INTERNATIONAL 43: 1851-1860, October 2010

Goreham-Voss CM, Hyde PJ, Hall RM, Fisher J, Brown TD. Cross-shear implementation in sliding-distance-coupled finite element analysis of wear in metal-on-polyethylene total joint arthroplasty: Intervertebral total disc replacement as an illustrative application. J BIOMECH 43(9):1674-1681, 18 June 2010

Kyle S, Aggeli A, Ingham E, McPherson MJ. Recombinant self-assembling peptides as biomaterials for tissue engineering. Biomaterials 31 9395-9405, 2010

Li X, Li D, Lian Q, Guo H, Jin Z. The effect of stem structure on stress distribution of a custom-made hip prosthesis. P I MECH ENG H 224(H11):1275-1284, 2010

Liu H, Ellison PJ, Xu H, Jin Z. Coupling of dynamics and contact mechanics of artificial hip joints in a pendulum model. P I MECH ENG H 224(H8):989-1003, 2010

Liu HP, Xu H, Ellison PJ, Jin ZM. Application of Computational Fluid Dynamics and Fluid-Structure Interaction Method to the Lubrication Study of a Rotor-Bearing System. TRIBOL LETT 38(3):325-336, June 2010

Luo Y, Ge SR, Jin ZM, Fisher J. Formation of titanium carbide coating with micro-porous structure. APPL PHYS A-MATER 98(4):765-768, March 2010

Luo Y, McCann L, Ingham E, Jin ZM, Ge S, Fisher J. Polyurethane as a potential knee hemiarthroplasty biomaterial: an in-vitro simulation of its tribological performance. P I MECH ENG H 224(H3):415-425, 2010

Meng Q, Gao L, Liu F, Yang P, Fisher J, Jin Z. Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface. J Biomech. 43(5):849-857, Marvh 2010

Meng QE, Liu F, Jin ZM. Elastohydrodynamic lubrication analysis of metal-on-metal hip implants with complex structures using the finite-element method. 36th Leeds-Lyon Symposium on Multi-Facets of Tribology, Inst Natl Sci Appliquees, Lyon, FRANCE, 01 Sep 2009 - 03 Sep 2009.. P IMechE PART J : J OF ENGINEERING TRIBOLOGY. 224: 1007-1018, 2010

O'Hara RM, Dunne NJ, Orr JF, Buchanan FJ, Wilcox RK, Barton DC. Optimisation of the mechanical and handling properties of an injectable calcium phosphate cement. 29th Northern Ireland Biomedical Engineering Conference, Queens Univ Belfast, Belfast, NORTH IRELAND, 08 Apr 2009. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE 21: 2299-2305, August 2010

Parry MC, Bhabra G, Sood A, Machado F, Cartwright L, Saunders M, Ingham E, Newson R, Blom AW, Case CP. Thresholds for indirect DNA damage across cellular barriers for orthopaedic biomaterials. BIOMATERIALS 31 4477-4483, 2010

Pawaskar SS, Fisher J, Jin ZM. Robust and General Method for Determining Surface Fluid Flow Boundary Conditions in Articular Cartilage Contact Mechanics Modeling. J BIOMECH ENG-T ASME 132(3) Art. No. 031001, 1-8, March 2010

Persson C, Evans S, Marsh R, Summers JL, Hall RM. Poisson's Ratio and Strain Rate Dependency of the Constitutive Behavior of Spinal Dura Mater. Ann Biomed Eng 38(3):975-983, March 2010

Sariali E, Stewart T, Jin Z, Fisher J. Three-dimensional modeling of in vitro hip kinematics under micro-separation regime for ceramic on ceramic total hip prosthesis: An analysis of vibration and noise. Journal of Biomechanics, 43 ( 2): 326-333, January 2010

Sariali E, Stewart E, MamoudyP, Jin Z, Fisher J. Undetected Fracture of an Alumina Ceramic on 3 Ceramic Hip Prosthesis. The Journal of Arthroplasty 25(4):658.e1-658.e5, June 2010

Sariali E, Stewart T, Jin Z, Fisher J. In vitro investigation of friction under edge loading conditions for ceramic-on-ceramic total hip prosthesis. J Orthop Res 28(8):979-985, August 2010

Vicars R, Hyde PJ, Brown TD, Tipper JL, Ingham E, Fisher J, Hall RM. The effect of anterior-posterior shear load on the wear of ProDisc-L TDR. Eur Spine J 19(8):1356-1362, August 2010

Wang M, Radjenovic A, Stapleton TW, Venkatesh R, Williams S, Ingham E, Fisher J, Jin Z. A novel and non-destructive method to examine meniscus architecture using 9.4 Tesla MRI. Osteoarthritis Cartilage 18(11):1417-1420, November 2010

Yan Y, Neville A, Dowson D, Williams S, Fisher J. Tribofilm formation in biotribocorrosion - does it regulate ion release in metal-on-metal artificial hip joints? 36th Leeds-Lyon Symposium on Multi-Facets of Tribology, Inst Natl Sci Appliquees, Lyon, FRANCE, 01 Sep 2009 - 03 Sep 2009. P IMechE PART J : J OF ENGINEERING TRIBOLOGY. 224: 997-1006, 2010

Yan Y, Neville A, Dowson D, Williams S, Fisher J. Electrochemical instrumentation of a hip simulator: a new tool for assessing the role of corrosion in metal-on-metal hip joints. P I MECH ENG H 224(H11):1267-1273, 2010

Zhao Y, Jin ZM, Wilcox RK. Modelling cement augmentation: a comparative experimental and finite element study at the continuum level. P I MECH ENG H 224(H7):903-911 2010